OPTIFLUX 2100 - Electromagnetic flowmeter
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
OPTIFLUX 2100 - Electromagnetic flowmeter – Process Meter for Industrial SystemsOPTIFLUX 2100 is a process-grade electromagnetic flowmeter engineered for reliable volumetric measurement of conductive liquids in industrial applications. Utilizing a non-intrusive lined flow tube and precision-excited coil assembly, the meter delivers stable analog and digital outputs for PLC/SCADA integration. The unit architecture features no moving parts, significantly reducing mechanical failure modes and pressure drop. Prepared for large-volume orders, units ship with serialized calibration and quality inspection records. Supply-readiness is managed through per-unit dimensional checks and functional verification, addressing the procurement requirements of facility engineers seeking durable, maintenance-free metering for manufacturing and commercial water systems. Packaging utilizes reinforced crates and corrosion-inhibiting liners for multimodal transport.Key FeaturesField-configurable electronics → adapts diagnostic thresholds and output scaling to specific site requirements for maximum control flexibility.Non-intrusive measurement head → eliminates moving parts to prevent flow path obstruction and reduce mechanical wear-out cycles in abrasive media.Flange-compatible body architecture → features standardized mechanical dimensions to simplify retrofits and new installations in existing industrial piping.Technical AttributesMeasurement Principle: Electromagnetic Induction → selection parameter defining suitability for conductive process liquids and effluents.Interface Standards: 4–20 mA / Pulse / Digital → ensures compatibility with diverse industrial automation and billing systems.Wetted Materials: Selectable Liners/Electrodes → selection parameter based on the chemical compatibility and abrasiveness of the media.Calibration: Individual Factory Certificate → provided per serial number to support site acceptance and institutional energy accounting.
The technical framework of the OPTIFLUX 2100 - Electromagnetic flowmeter utilizes a precision-lined metallic flow tube surrounded by a bipolar excitation coil system. The structural reasoning for the lined bore is to provide an essential electrical boundary between the process fluid and the sensor body. measurement physics rely on Faraday’s Law; as conductive liquid passes through the magnetic field, a voltage proportional to the flow velocity is induced across the flush-mounted electrodes. A failure in the liner bonding—due to localized thermal shock or chemical etching—leads to "liner collapse," manifesting as signal noise and a total loss of Span accuracy. This failure mode decommissions the meter and can lead to external leakage if the process fluid breaches the secondary seals. The coil geometry is specifically tuned to generate a uniform magnetic field across the measurement plane. Quality consistency is managed through serialized dimensional control of the bore and magnetic-field verification. The mechanical layout features a separate electronics compartment to reduce thermal conduction from the process line to the delicate signal converters.
Operational efficiency is achieved through the meter’s high stability and near-zero pressure drop, which reduces the facility's pumping energy overhead. Functional performance centers on the unit’s integrated diagnostics; the transmitter monitors electrode grounding and signal-to-noise ratios in real-time. In a real operational scenario, a failure to manage the "grounding integrity"—especially in plastic piping systems—leads to common-mode errors that result in inaccurate volumetric totals. The OPTIFLUX 2100 utilizes high-speed digital signal processing to filter out electrical noise from nearby high-power pumps—a failure to suppress this noise results in "signal jitter," decommissioning the feedback control for blending operations. The modular electronics design effectively lowers the mean time to repair (MTTR) by allowing for field exchange without removing the flow body from the line. if the unit detects a coil fault or an empty pipe condition, it triggers a diagnostic alarm via its digital interface, providing B2B managers with event-driven maintenance data for preventive planning.
Designed for manufacturing plants, commercial water systems, and process control loops, the OPTIFLUX 2100 is configured for the logistical requirements of project-scale procurement. Units ship in reinforced crates with internal bracing and shock indicators to protect the sensitive sensor alignment during transit. Failure to implement shock-mitigating packaging can lead to microscopic displacement of the electrode mounts, resulting in signal drift upon site commissioning. For international procurement, supply-readiness is supported by lot-specific calibration certificates and compliance declarations (CE/IEC). Export-ready documentation include unit configuration snapshots and certificates of origin provided with each consignment to facilitate institutional asset registration and customs review. Packaging utilize vapor-barrier liners and desiccant to prevent terminal oxidation during maritime transit. OEM production agreements are supported, allowing for custom labeling and branded enclosures. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets, providing the technical transparency required for large-scale infrastructure rollouts.
Description provided by shakti power solutions pvt limited.
| Model Name/Number | OPTIFLUX 2100 |
|---|---|
| Media Type | Any conductive liquid (≥5 μS/cm) |
| Measurement Principle | Electromagnetic |
| Maximum Process Pressure | 16 barg / 230 psig |
| Temperature Range | -25°C to +120°C (-13°F to +248°F) |
| Liner Material | Perfluoroalkoxy alkane (PFA) |
| Electrode Material | Hastelloy® |
| Certifications | ATEX, FM, CSA, ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS |
| Communication Interfaces | 3 x 4–20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET |
| Pipe Size | DN10…150 / ⅜…6 inches |
| Design Type | Wafer-style (sandwich) |
| Turndown Ratio | 1000:1 |
| Solid Content Capability | Up to 70% solid content |
| Maintenance | Maintenance-free |
| On-site Verification | Available via OPTICHECK tool |
| Category | Flow Measurement Instruments > Electromagnetic Flowmeters |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |
Common questions B2B buyers ask before sourcing OPTIFLUX 2100 - Electromagnetic flowmeter. Answers compiled from verified sellers' commercial terms and platform data.
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Post one RFQ and get quotes from all verified sellers within 48 hours. No commitment, no spam.