1/2
FIEO Registered FIEO Registered Export Ready

OPTIFLUX 2100 - Electromagnetic flowmeter

Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India

Price
Price on request
In stock
Minimum order: 1 unit

Export Snapshot

MOQ
1 unit
Lead time
On request
Packaging
Standard export packaging
Shelf life / longevity
As per product specification
HS Code
On request
Origin
India
Port of dispatch
On request
Export markets served
Global markets
Values shown are for shakti power solutions pvt limited.
Compliance & Certifications
FIEO Registered FIEO Registered
Suitable for

Importers · Distributors · Wholesalers

Know your supplier

shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.

Amritsar Dispatch on request FIEO member
shakti power solutions pvt limited logo

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India

Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.

Established
Not shared
Employees
GST
03ABGCS0227D1ZZ
IEC code
Not shared
Export markets
Global markets
GlobalLinker Member Since
Dec 2018
Turnover
Incorporation Type
On request
Product details

What are the specifications of this product?

Overview

OPTIFLUX 2100 - Electromagnetic flowmeter – Process Meter for Industrial SystemsOPTIFLUX 2100 is a process-grade electromagnetic flowmeter engineered for reliable volumetric measurement of conductive liquids in industrial applications. Utilizing a non-intrusive lined flow tube and precision-excited coil assembly, the meter delivers stable analog and digital outputs for PLC/SCADA integration. The unit architecture features no moving parts, significantly reducing mechanical failure modes and pressure drop. Prepared for large-volume orders, units ship with serialized calibration and quality inspection records. Supply-readiness is managed through per-unit dimensional checks and functional verification, addressing the procurement requirements of facility engineers seeking durable, maintenance-free metering for manufacturing and commercial water systems. Packaging utilizes reinforced crates and corrosion-inhibiting liners for multimodal transport.Key FeaturesField-configurable electronics → adapts diagnostic thresholds and output scaling to specific site requirements for maximum control flexibility.Non-intrusive measurement head → eliminates moving parts to prevent flow path obstruction and reduce mechanical wear-out cycles in abrasive media.Flange-compatible body architecture → features standardized mechanical dimensions to simplify retrofits and new installations in existing industrial piping.Technical AttributesMeasurement Principle: Electromagnetic Induction → selection parameter defining suitability for conductive process liquids and effluents.Interface Standards: 4–20 mA / Pulse / Digital → ensures compatibility with diverse industrial automation and billing systems.Wetted Materials: Selectable Liners/Electrodes → selection parameter based on the chemical compatibility and abrasiveness of the media.Calibration: Individual Factory Certificate → provided per serial number to support site acceptance and institutional energy accounting.

Product Description

Structural Design and Sensing Logic of the OPTIFLUX 2100

The technical framework of the OPTIFLUX 2100 - Electromagnetic flowmeter utilizes a precision-lined metallic flow tube surrounded by a bipolar excitation coil system. The structural reasoning for the lined bore is to provide an essential electrical boundary between the process fluid and the sensor body. measurement physics rely on Faraday’s Law; as conductive liquid passes through the magnetic field, a voltage proportional to the flow velocity is induced across the flush-mounted electrodes. A failure in the liner bonding—due to localized thermal shock or chemical etching—leads to "liner collapse," manifesting as signal noise and a total loss of Span accuracy. This failure mode decommissions the meter and can lead to external leakage if the process fluid breaches the secondary seals. The coil geometry is specifically tuned to generate a uniform magnetic field across the measurement plane. Quality consistency is managed through serialized dimensional control of the bore and magnetic-field verification. The mechanical layout features a separate electronics compartment to reduce thermal conduction from the process line to the delicate signal converters.

Functional Performance and Operational Efficiency in Process Control

Operational efficiency is achieved through the meter’s high stability and near-zero pressure drop, which reduces the facility's pumping energy overhead. Functional performance centers on the unit’s integrated diagnostics; the transmitter monitors electrode grounding and signal-to-noise ratios in real-time. In a real operational scenario, a failure to manage the "grounding integrity"—especially in plastic piping systems—leads to common-mode errors that result in inaccurate volumetric totals. The OPTIFLUX 2100 utilizes high-speed digital signal processing to filter out electrical noise from nearby high-power pumps—a failure to suppress this noise results in "signal jitter," decommissioning the feedback control for blending operations. The modular electronics design effectively lowers the mean time to repair (MTTR) by allowing for field exchange without removing the flow body from the line. if the unit detects a coil fault or an empty pipe condition, it triggers a diagnostic alarm via its digital interface, providing B2B managers with event-driven maintenance data for preventive planning.

Institutional Deployment and Logistical Readiness for multi-site rollouts

Designed for manufacturing plants, commercial water systems, and process control loops, the OPTIFLUX 2100 is configured for the logistical requirements of project-scale procurement. Units ship in reinforced crates with internal bracing and shock indicators to protect the sensitive sensor alignment during transit. Failure to implement shock-mitigating packaging can lead to microscopic displacement of the electrode mounts, resulting in signal drift upon site commissioning. For international procurement, supply-readiness is supported by lot-specific calibration certificates and compliance declarations (CE/IEC). Export-ready documentation include unit configuration snapshots and certificates of origin provided with each consignment to facilitate institutional asset registration and customs review. Packaging utilize vapor-barrier liners and desiccant to prevent terminal oxidation during maritime transit. OEM production agreements are supported, allowing for custom labeling and branded enclosures. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets, providing the technical transparency required for large-scale infrastructure rollouts.

Frequently Asked Questions

  • What conductivity range is required? The process liquid must meet the minimum conductivity threshold (typically >5 μS/cm) for reliable electromagnetic induction.
  • Are different liner materials offered? Yes, liners are selectable based on temperature and chemical profiles (e.g., Polyurethane or Hard Rubber).
  • How is measurement drift managed? Drift is compensated via stable coil excitation and internal diagnostic checks; annual verification is recommended.
  • What packaging protects the unit in transit? Units are shipped in reinforced wooden crates with vapor-barrier liners and moisture desiccant.
  • Which documents accompany the meter? Each consignment includes serialized calibration certificates, functional test reports, and technical manuals.

Description provided by shakti power solutions pvt limited.

Specifications

Model Name/Number OPTIFLUX 2100
Media Type Any conductive liquid (≥5 μS/cm)
Measurement Principle Electromagnetic
Maximum Process Pressure 16 barg / 230 psig
Temperature Range -25°C to +120°C (-13°F to +248°F)
Liner Material Perfluoroalkoxy alkane (PFA)
Electrode Material Hastelloy®
Certifications ATEX, FM, CSA, ABS, BV, CCS, DNV, KR, LR, NK, RINA, CRS, IRS, PRS
Communication Interfaces 3 x 4–20 mA, HART®, Modbus, FF, Profibus-PA/DP, PROFINET
Pipe Size DN10…150 / ⅜…6 inches
Design Type Wafer-style (sandwich)
Turndown Ratio 1000:1
Solid Content Capability Up to 70% solid content
Maintenance Maintenance-free
On-site Verification Available via OPTICHECK tool

Use cases

Category Flow Measurement Instruments > Electromagnetic Flowmeters
Primary application Wholesale, distribution, and international sourcing
Brand shakti power solutions
Product type Product

Logistics & handling

Lead time On request
Packaging As per buyer requirement
Storage condition As recommended by supplier
Origin India
Form As listed by supplier

Commercials (this seller)

Minimum order 1 unit
Lead time On request
Payment terms As per negotiated commercial agreement.
Checkout type enquiry
Buyer questions

Frequently asked by buyers

Common questions B2B buyers ask before sourcing OPTIFLUX 2100 - Electromagnetic flowmeter. Answers compiled from verified sellers' commercial terms and platform data.

Q: Can OPTIFLUX 2100 handle liquids with high solid content?
A: Yes, OPTIFLUX 2100 can accurately measure liquids with up to 70% solid content, including slurries with non-abrasive solid particles.
Q: Is the OPTIFLUX 2100 suitable for hazardous environments?
A: Yes, the flowmeter is certified with ATEX, FM, and CSA approvals, making it safe for use in classified hazardous zones.
Q: What types of communication protocols does the OPTIFLUX 2100 support?
A: It supports multiple communication protocols including 3 x 4-20 mA, HART®, Modbus, FF, Profibus-PA/DP, and PROFINET.
Q: Does the OPTIFLUX 2100 require regular maintenance?
A: No, due to its design with no internal moving parts, the OPTIFLUX 2100 is maintenance-free.
Q: How can I verify the flowmeter's calibration without process interruption?
A: You can perform an on-site verification using the OPTICHECK service tool without needing to stop the process.
Question not answered? Ask sellers directly — typical response within 4 hours.
shakti power solutions sd 200 multiparameter indicator for analytical and other parameters
shakti power solutions sd 200 multiparameter indicator for analytical and other parameters
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-s50 resistance (rtd) temperature assembly for use in existing thermowells or machinery
shakti power solutions optitemp tra-s50 resistance (rtd) temperature assembly for use in existing thermowells or machinery
Price on request MOQ 1 unit
View Product
shakti power solutions optibar dp 7060 differential pressure transmitter for flow, level, differential pressure, density
shakti power solutions optibar dp 7060 differential pressure transmitter for flow, level, differential pressure, density
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-f42 thermocouple (tc) temperature assembly for standard applications
shakti power solutions optitemp tca-f42 thermocouple (tc) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-s11 thermocouple (tc) temperature assembly for lower temperature applications
shakti power solutions optitemp tca-s11 thermocouple (tc) temperature assembly for lower temperature applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-p65 thermocouple (tc) temperature assembly for high temperature applications
shakti power solutions optitemp tca-p65 thermocouple (tc) temperature assembly for high temperature applications
Price on request MOQ 1 unit
View Product
shakti power solutions optiswitch 6500 capacitance level switch for advanced hygienic applications
shakti power solutions optiswitch 6500 capacitance level switch for advanced hygienic applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-tf55 thermocouple (tc) temperature assembly for higher flow velocities and pressures
shakti power solutions optitemp tca-tf55 thermocouple (tc) temperature assembly for higher flow velocities and pressures
Price on request MOQ 1 unit
View Product
shakti power solutions optiwave 6400 radar (fmcw) level transmitter for solids from granulates to rocks
shakti power solutions optiwave 6400 radar (fmcw) level transmitter for solids from granulates to rocks
Price on request MOQ 1 unit
View Product
shakti power solutions optiwave 5400 radar (fmcw) level transmitter for liquids in basic process applications
shakti power solutions optiwave 5400 radar (fmcw) level transmitter for liquids in basic process applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-ts37 thermocouple (tc) temperature assembly for higher flow velocities and pressures
shakti power solutions optitemp tca-ts37 thermocouple (tc) temperature assembly for higher flow velocities and pressures
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-g20 resistance (rtd) temperature assembly for surface temperature measurement
shakti power solutions optitemp tra-g20 resistance (rtd) temperature assembly for surface temperature measurement
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-p40 resistance (rtd) temperature assembly for standard applications
shakti power solutions optitemp tra-p40 resistance (rtd) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-p10 resistance (rtd) temperature assembly for standard applications
shakti power solutions optitemp tra-p10 resistance (rtd) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-v10 resistance (rtd) compact sensor for measuring indoor air temperature in hvac
shakti power solutions optitemp tra-v10 resistance (rtd) compact sensor for measuring indoor air temperature in hvac
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-g10 resistance (rtd) temperature assembly for surface temperature measurement
shakti power solutions optitemp tra-g10 resistance (rtd) temperature assembly for surface temperature measurement
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
OPTIFLUX 2100 - Electromagnetic flowmeter
OPTIFLUX 2100 - Electromagnetic flowmeter
Price on request · MOQ 1unit