1/2
FIEO Registered FIEO Registered Export Ready

OPTIFLUX 4400 - Electromagnetic flowmeter

Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India

Price
Price on request
In stock
Minimum order: 1 unit

Export Snapshot

MOQ
1 unit
Lead time
On request
Packaging
Standard export packaging
Shelf life / longevity
As per product specification
HS Code
On request
Origin
India
Port of dispatch
On request
Export markets served
Global markets
Values shown are for shakti power solutions pvt limited.
Compliance & Certifications
FIEO Registered FIEO Registered
Suitable for

Importers · Distributors · Wholesalers

Know your supplier

shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.

Amritsar Dispatch on request FIEO member
shakti power solutions pvt limited logo

Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India

Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.

Established
Not shared
Employees
GST
03ABGCS0227D1ZZ
IEC code
Not shared
Export markets
Global markets
GlobalLinker Member Since
Dec 2018
Turnover
Incorporation Type
On request
Product details

What are the specifications of this product?

Overview

OPTIFLUX 4400 - Electromagnetic flowmeter – Industrial Utility FlowmeterOPTIFLUX 4400 is a high-integrity electromagnetic flowmeter engineered for heavy-duty industrial and utility volumetric measurement. Utilizing a reinforced metallic body and a precision-engineered liner, the unit delivers stable measurement in high-pressure pipelines with minimal structural deformation. The architecture features an advanced electrode network and modular electronics to support SCADA integration and real-time process monitoring. Delivered with lot-specific calibration and factory inspection reports, the unit ensures supply-readiness for large-scale utility infrastructure. Packaging includes moisture-barrier liners and internal bracing for consolidated multimodal transport. This component is essential for facilities requiring non-intrusive, maintenance-free flow feedback with documented accuracy class for institutional energy accounting.Key FeaturesHeavy-duty body construction → engineered to withstand high mechanical stress and pressure surges in utility-scale pipelines without compromising bore geometry.Precision electrode network → utilizes specialized placement and metallurgy to ensure high-fidelity signal sampling across the entire flow cross-section.Modular electronics interface → features field-replaceable signal converters and configurable outputs (Analog/Digital) to simplify site commissioning and future upgrades.Technical AttributesMeasurement Principle: Faraday’s Induction → selection parameter defining suitability for all conductive liquids and effluents.Liner Materials: Application-specific → selection based on chemical aggressiveness, temperature, and abrasion resistance of the media.Turndown Ratio: High-linearity → ensures accurate measurement across wide fluctuations in volumetric flow rates common in municipal systems.Calibration: Serialized Unit Records → provided per serial number to support procurement quality checks and regulatory compliance.

Product Description

Structural Composition and Electromagnetic Logic of the OPTIFLUX 4400

The technical framework of the OPTIFLUX 4400 utilizes a lined metallic flow tube surrounded by high-density excitation coils that generate a uniform magnetic field. The structural reasoning for the reinforced body is to maintain "bore stability" under the massive flange bolting forces and hydraulic pressures typical of utility mains. A failure in structural rigidity results in "bore ovalization," which manifests as localized stress on the dielectric liner and measurement bias—a failure mode that decommissions the accuracy of the entire billing or control node. measurement physics rely on the voltage induced across the electrodes as conductive liquid passes through the magnetic field. A failure in the coil potting—typically due to moisture ingress—leads to "excitation imbalance," resulting in signal noise and erratic volumetric reports. Quality consistency is managed through manufacturing controls that verify bore concentricity and 100% magnetic-field uniformity. The internal PCBA is protected by specialized shielding to minimize EMI coupling from nearby high-power pumps, ensuring a stable zero-point even in dense industrial environments.

Functional Performance and Operational Efficiency in Utility Networks

Operational efficiency is achieved through the meter’s non-intrusive design, which results in near-zero pressure loss, effectively reducing the facility’s pumping energy overhead. Functional performance centers on the unit’s integrated diagnostics; the transmitter monitors electrode impedance and signal quality in real-time. In a real operational scenario, a failure to manage "electrode fouling"—caused by scale or grease buildup—leads to signal attenuation and measurement drift. The 4400 utilize adaptive signal processing to identify these trends before they decommissioning the loop. If the electronics module detects an internal logic fault, the modular design allows for in-field hardware swaps without removing the flow tube from the pipeline, effectively lowering the mean time to repair (MTTR). By providing a stable and traceable signal, the meter improves the facility's situational awareness, reducing the need for manual site inspections and supporting automated energy accounting protocols required for institutional facility management.

Institutional Deployment and Logistical Readiness for Infrastructure

Designed for large industrial installations, municipal water networks, and OEM process skids, the OPTIFLUX 4400 is configured for the logistical requirements of project-scale procurement. Units ship in reinforced crates with internal rigid bracing and shock indicators to protect the sensitive sensor alignment during multimodal transit. Failure to implement shock-mitigating packaging can lead to microscopic fractures in the liner-to-flange interface, resulting in external leakage upon site commissioning. For international procurement, supply-readiness is supported through serialized calibration certificates and compliance declarations (ISO/CE). Export-ready documentation includes unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize humidity-control liners and desiccant to prevent finish degradation and terminal oxidation during maritime freight. OEM branding and custom firmware options are available for system builders requiring branded instrumentation suites. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets.

Frequently Asked Questions

  • What conductivity range is required? The meter requires a minimum fluid conductivity of 5 μS/cm for reliable signal induction.
  • Can the electronics be serviced while the pipe is full? Yes; the modular transmitter can be replaced without breaching the process containment boundary.
  • How is moisture risk managed in the field? Housing is gasket-sealed to IP66/67 with optional potting for high-humidity installations.
  • What documentation is provided? Shipments include factory calibration certificates, lot inspection reports, and conformity declarations.
  • Is it suitable for abrasive media? Selection of hardened liners (e.g., Hard Rubber) and specific electrodes allows operation in high-solid effluents.

Description provided by shakti power solutions pvt limited.

Specifications

Display Digital
Measured Media Liquids
Measurement Principle Electromagnetic
Process Temperature Range -25°C to +120°C
Process Pressure Max. 16 barg / 230 psig
Product Type Flowmeter
Availability In Stock
Pipe Diameter DN10…150 (⅜…6 inches)
Nominal Pressure Max. PN40 / ASME Cl 300
Output Signal 4–20 mA, pulse, frequency, status, HART®, Modbus
Liner Material Reinforced PFA
Electrode Material Hastelloy®

Use cases

Category Industrial Flowmeters>Electromagnetic Flowmeters
Primary application Wholesale, distribution, and international sourcing
Brand shakti power solutions
Product type Product

Logistics & handling

Lead time On request
Packaging As per buyer requirement
Storage condition As recommended by supplier
Origin India
Form As listed by supplier

Commercials (this seller)

Minimum order 1 unit
Lead time On request
Payment terms As per negotiated commercial agreement.
Checkout type enquiry
Buyer questions

Frequently asked by buyers

Common questions B2B buyers ask before sourcing OPTIFLUX 4400 - Electromagnetic flowmeter. Answers compiled from verified sellers' commercial terms and platform data.

Q: Can the OPTIFLUX 4400 be used for high solid content liquids?
A: The OPTIFLUX 4400 is designed for liquids with low solid content up to 10%. It may not provide accurate measurements for liquids with higher solid content.
Q: Is the OPTIFLUX 4400 suitable for installation in high humidity environments?
A: Yes, the flowmeter features extra isolation of its electronics and housing, making it suitable for operation in areas with extreme humidity.
Q: Does the OPTIFLUX 4400 require maintenance?
A: No, the flowmeter has no internal moving parts, which reduces wear and eliminates the need for regular maintenance.
Q: What communication protocols does the OPTIFLUX 4400 support?
A: It supports multiple communication outputs including 4-20 mA current, active pulse/frequency output, HART®, and Modbus protocols.
Q: Can the flowmeter be verified without process interruption?
A: Yes, on-site verification can be performed using the OPTICHECK service tool without interrupting the process flow.
Question not answered? Ask sellers directly — typical response within 4 hours.
shakti power solutions optitemp tca-tf55 thermocouple (tc) temperature assembly for higher flow velocities and pressures
shakti power solutions optitemp tca-tf55 thermocouple (tc) temperature assembly for higher flow velocities and pressures
Price on request MOQ 1 unit
View Product
shakti power solutions optiwave 6400 radar (fmcw) level transmitter for solids from granulates to rocks
shakti power solutions optiwave 6400 radar (fmcw) level transmitter for solids from granulates to rocks
Price on request MOQ 1 unit
View Product
shakti power solutions optiwave 5400 radar (fmcw) level transmitter for liquids in basic process applications
shakti power solutions optiwave 5400 radar (fmcw) level transmitter for liquids in basic process applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-ts37 thermocouple (tc) temperature assembly for higher flow velocities and pressures
shakti power solutions optitemp tca-ts37 thermocouple (tc) temperature assembly for higher flow velocities and pressures
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-g20 resistance (rtd) temperature assembly for surface temperature measurement
shakti power solutions optitemp tra-g20 resistance (rtd) temperature assembly for surface temperature measurement
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-p40 resistance (rtd) temperature assembly for standard applications
shakti power solutions optitemp tra-p40 resistance (rtd) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-p10 resistance (rtd) temperature assembly for standard applications
shakti power solutions optitemp tra-p10 resistance (rtd) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-v10 resistance (rtd) compact sensor for measuring indoor air temperature in hvac
shakti power solutions optitemp tra-v10 resistance (rtd) compact sensor for measuring indoor air temperature in hvac
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-g10 resistance (rtd) temperature assembly for surface temperature measurement
shakti power solutions optitemp tra-g10 resistance (rtd) temperature assembly for surface temperature measurement
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions sd 200 multiparameter indicator for analytical and other parameters
shakti power solutions sd 200 multiparameter indicator for analytical and other parameters
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tra-s50 resistance (rtd) temperature assembly for use in existing thermowells or machinery
shakti power solutions optitemp tra-s50 resistance (rtd) temperature assembly for use in existing thermowells or machinery
Price on request MOQ 1 unit
View Product
shakti power solutions optibar dp 7060 differential pressure transmitter for flow, level, differential pressure, density
shakti power solutions optibar dp 7060 differential pressure transmitter for flow, level, differential pressure, density
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-f42 thermocouple (tc) temperature assembly for standard applications
shakti power solutions optitemp tca-f42 thermocouple (tc) temperature assembly for standard applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-s11 thermocouple (tc) temperature assembly for lower temperature applications
shakti power solutions optitemp tca-s11 thermocouple (tc) temperature assembly for lower temperature applications
Price on request MOQ 1 unit
View Product
shakti power solutions optitemp tca-p65 thermocouple (tc) temperature assembly for high temperature applications
shakti power solutions optitemp tca-p65 thermocouple (tc) temperature assembly for high temperature applications
Price on request MOQ 1 unit
View Product
shakti power solutions optiswitch 6500 capacitance level switch for advanced hygienic applications
shakti power solutions optiswitch 6500 capacitance level switch for advanced hygienic applications
Price on request MOQ 1 unit
View Product
OPTIFLUX 4400 - Electromagnetic flowmeter
OPTIFLUX 4400 - Electromagnetic flowmeter
Price on request · MOQ 1unit