DK46/47/48/800 - Variable area flowmeter
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
DK46/47/48/800 Variable Area Flowmeter – Industrial Variable-Area FamilyDK46/47/48/800 Variable Area Flowmeter is a modular family of float-type measurement instruments engineered for industrial volumetric metering across a wide range of process fluids and gases. Utilizing interchangeable tube and float assemblies, the unit architecture adapts to diverse process chemistries and flow rates with minimal downtime. The design features robust construction with multiple material options for wetted parts, delivering repeatable measurement in demanding industrial environments. Supplied with batch calibration certificates and QA documentation, units are prepared for plant acceptance tests and multi-site rollouts. Supply-readiness is managed through factory-verified performance logs and configuration reports, addressing the requirements of institutional procurement teams seeking standardized instrumentation fleets. Packaging utilizes reinforced crating and moisture-barrier protection to ensure the integrity of the modular components during long-haul transit.Key FeaturesModular tube and float architecture → enables rapid field reconfiguration for different fluids or flow ranges, effectively reducing the requirement for large spares inventories.Engineering-unit scale markings → features direct-reading scales calibrated for specific industrial media to simplify process monitoring and reduce operator error.Field-serviceable components → utilize a non-complex mechanical layout to facilitate rapid mean time to repair (MTTR) and ensure high system availability in process bypass streams.Technical AttributesRangeability: Multi-model Selection → selection parameter based on the minimum and maximum expected flow rates for the process node.Connection Options: Flanged / Threaded → determines mechanical compatibility with existing plant piping and defines maintenance access.Material Compatibility: Wide Array → selection parameter for matching process chemistry and temperature to ensure sensor durability.Traceability: Batch Calibration → provided per lot to support procurement quality checks and institutional asset management.
The technical framework of the DK46/47/48/800 series utilizes a modular construction where a variety of tapered tubes (plastic or glass) and floats (stainless steel, titanium, or polymer) can be paired. The structural reasoning for this modularity is to provide "chemical and mechanical versatility"—facility managers can adapt the meter to aggressive acids or light gases by simply swapping the internal stack. measurement physics rely on the vertical displacement of the float; a failure in the float's dimensional stability—due to chemical swelling or thermal expansion—results in "range shift," where the meter reports inaccurate volumetric data. This failure mode decommissions the accuracy of localized dosing systems and can lead to process quality deviations. Quality consistency is managed through manufacturing controls that verify the tapered profile and float mass. Failure to management the "media viscosity"—due to incorrect sizing—results in float instability, manifesting as erratic readings in high-viscosity applications. The internal layout is designed to be purely mechanical, providing an essential "fail-safe" measurement point during facility power outages.
Operational efficiency is achieved through the unit’s ability to provide stable readings at steady low-to-medium flows, an essential operational standard for monitoring utility bypass and chemical injection loops. functional performance centers on the unit’s support for local visual indication; failure to maintain the tube’s transparency—due to scale buildup—results in the loss of process visibility. To mitigate this, the DK series utilize accessible clean-out ports and chemically-resistant materials. In a real operational scenario, a failure in the grounding for optional limit switches—used for high/low flow alarms—leads to signal noise that triggers nuisance process trips. The unit utilizes high-sampling-rate calibration rigs to ensure the scale markings match the physical response of the float to within ±1-3% accuracy. if the float becomes chipped or worn—due to abrasive solids—the measurement zero-point shifts, effectively decommissioning the meter. By Providing a stable and maintenance-free signal, the series effectively improves the reliability of the localized water management and dosing systems, providing the technical transparency required for institutional maintenance audits.
Designed for chemical dosing, utility monitoring, and process bypass streams, the DK series is configured for the logistical requirements of project-scale multi-unit procurement. Units ship in reinforced crates with internal rigid bracing and moisture-barrier film to protect the sensitive internal inductors and gold-plated electrode contacts (where limit switches are fitted). Failure to implement finish-protected packaging results in "terminal pitting," manifesting as intermittent power loss upon site commissioning. For international procurement, supply-readiness is supported through lot-specific test certificates and material trace records (EN 10204). Export-ready documentation include unit configuration snapshots and certificates of origin to facilitate institutional asset registration. Packaging utilize humidity-control liners and desiccant to prevent terminal oxidation during maritime transit. OEM branding and private-label firmware profiles (for electronic variants) are available, allowing system integrators to deliver branded suites with serialized records. This high-authority approach ensure procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets.
Description provided by shakti power solutions pvt limited.
| Material | Stainless Steel |
|---|---|
| Size Range | 3" to 18" (80 mm to 450 mm) |
| Design Standard | ASME B 16.34 |
| ASME Class | 900 to 4100 |
| Valve Type | Pressure-seal Globe Valve |
| Seat Thickness | 3 mm hardfacing thickness |
| Certifications | SIL 3, CE Marking (PED 2014/68/EU), ATEX 94/9/EC |
| Testing | ISO 15848-1 Class BH and Shell Design Validation Test 77/300 |
| Valve Body Construction | Cast and forged steel, exotic metallurgies available |
| Packing | High purity seven-ring graphite packing for Class >2500 |
| Additional Features | By-pass arrangement, ValvTrac™ RFID tagging |
| Category | Industrial Flow Measurement Instruments > Variable Area Flowmeters |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |
Common questions B2B buyers ask before sourcing DK46/47/48/800 - Variable area flowmeter. Answers compiled from verified sellers' commercial terms and platform data.
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Post one RFQ and get quotes from all verified sellers within 48 hours. No commitment, no spam.
Post a RFQ