Vertiv Liebert RG 40 - 250kVA
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
Vertiv Liebert RG 40-250 kVA UPS – Three-phase High-Capacity SystemVertiv Liebert RG 40-250 kVA is a modular three-phase power protection system engineered for medium-to-large data halls and industrial critical loads. utilizing a scalable architecture, the unit delivers contiguous power from 40 kVA up to 250 kVA through parallel-redundant modules. The unit architecture features hot-swappable power stages and distributed monitoring logic to eliminate single points of failure and maximize facility uptime. Units are available for large-volume distribution, shipping on frame-mounted skids with comprehensive factory acceptance test (FAT) dossiers. Supply-readiness is managed through per-module functional verification and load-sharing reports, addressing the requirements of facility engineers seeking high-availability power with documented redundancy for institutional energy accounting and multi-site rollouts. Packaging includes reinforced crating and moisture-barrier covers to preserve structural integrity during international logistics.Key FeaturesModular capacity scaling → provides a scalable energy solution where modules can be added in-field to grow with the facility’s power demand without system decommissioning.Parallel-redundant architecture → utilizes N+1 redundancy logic to ensure continuous load protection even during a single module outage or maintenance event.Service-oriented access panels → features front-access modules and tool-accessible cabinets to reduce mean time to repair (MTTR) and simplify routine inspections.Technical AttributesPower Range: 40–250 kVA per Cabinet → selection parameter for centralized data center power planning and infrastructure design.Topology: 3-Phase Double Conversion → ensures complete isolation of the load from mains disturbances, delivering a pure AC sine-wave output.Cooling: Integrated Forced-Air → features high-velocity fans sized for sustained 24/7 operation under full rated capacity.Interface Suite: SNMP / Modbus + Local HMI → determines the system’s ability to integrate with centralized SCADA and building management platforms.
The technical framework of the Vertiv Liebert RG 40-250 kVA utilizes a high-density metallic frame containing discrete power, bypass, and control modules arranged for rapid field exchange. The structural reasoning for the modular isolation is to provide "fault containment"—a failure in one module—due to IGBT breakdown or DC capacitor dry-out—cannot propagate across the common high-current buswork. measurement physics rely on high-fidelity current sensors that coordinate parallel load-sharing to within ±1% accuracy. A failure in the synchronization bus results in "circulating currents," manifesting as localized thermal hotspots and potential terminal melting. quality consistency is managed through serialized FAT dossiers documenting load-transfer efficiency and harmonic emission levels. The internal chassis uses insulated bus-duct technology and reinforced structural stiffeners to manage the electromagnetic forces of high-mass energy systems, a critical standard for protecting the sensitive logic from the mechanical resonance of nearby facility machinery.
Operational efficiency is achieved through the unit’s online double-conversion logic, which delivers peak efficiency across a wide load window (25-100%), an essential operational standard for reducing facility PUE (Power Usage Effectiveness). functional performance centers on the unit’s support for active thermal management; if the unit detects a fan failure in a power module, it triggers a diagnostic alarm and initiates a load-redistribution sequence to the remaining parallel units. In a real operational scenario, a failure in the phase-balancing logic leads to localized semiconductor fatigue, decommissioning the module. The RG series utilizes independent phase regulation to mitigate this risk. if the internal moisture seal is breached, moisture carry-over from the ventilation path can cause tracking faults; the unit utilizes conformally coated electronics and IP-rated control bays to prevent this outcome. maintenance procedures are simplified by the front-access design, effectively lowering the mean time to repair (MTTR). By providing detailed telemetry on harmonic rejection and load profiles, the UPS allows B2B facility managers to accurately account for energy throughput and implement predictive maintenance routines before a component failure occur.
Designed for large data centers, industrial control rooms, and hospital power cores, the RG 40-250 kVA is configured for the logistical requirements of multimodal procurement. Units ship on reinforced skids with internal rigid bracing and moisture-barrier film to protect the sensitive inductors and logic processors during transit. Failure to implement shock-mitigating packaging can lead to "chassis racking," which manifests as door misalignment or high-resistance electrical joints upon site arrival. For international procurement, supply-readiness is supported through serialized test records and compliance declarations (ISO/CE). Export-ready documentation include unit configuration snapshots and commissioning checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize vapor-barrier covers and desiccants to prevent terminal oxidation during maritime freight. OEM branding and custom façade options are available for system builders requiring branded suites. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global markets.
Description provided by shakti power solutions pvt limited.
| Model Name/Number | LIEBERT GXTMT+CX2KVA (EXTERNAL BATTERY) |
|---|---|
| Capacity | 2000 VA / 1800 W |
| Usage/Application | Industrial |
| Battery Type | 12 V / 9 AH (External Battery) |
| Weight | Not specified |
| Dimensions (mm) | 397 x 145 x 220 |
| Availability | In Stock |
| Technology | GBT-based Rectifier, DSP Control Technology |
| Input Power Factor | 0.99 |
| Output Power Factor | 0.9 |
| Input Voltage Window | 280 VAC |
| Input Frequency Range | 40Hz–70Hz |
| Category | Industrial UPS Systems |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |