Eaton 93 PR 300-1200 KVA/ KW, >80 KVA
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
Eaton 93 PR 300-1200 KVA/ KW, >80 KVA – Modular High-Capacity UPSEaton 93 PR 300-1200 KVA/ KW is a high-availability modular three-phase power system engineered for hyperscale data centers and centralized industrial power cores. utilizing a transformer-free double-conversion topology, the system delivers contiguous power from 300 kW up to 1200 kW in 60 kW increments. The unit architecture features hot-swappable power modules and a high-density footprint to maximize facility floor efficiency. Units are offered with comprehensive factory acceptance test (FAT) dossiers and module-level serialization. Supply-readiness is managed through factory-verified load-sharing and harmonics reports, addressing the requirements of facility engineers seeking scalable, high-efficiency power protection with documented redundancy for institutional asset management and multi-site rollouts. Packaging includes reinforced skids and shock-monitoring hardware for safe multimodal transport.Key FeaturesScalable modular architecture → allows capacity growth from 300 kW to 1200 kW in 60 kW building blocks, enabling facility managers to scale power alongside IT load evolution without system decommissioning.Hot-swap modularity → features power stages that can be serviced or replaced while the UPS remains online under full load, ensuring zero downtime for mission-critical infrastructure.High efficiency load management → utilize active energy optimization to achieve peak conversion efficiency even during partial-load conditions, significantly reducing facility cooling energy overhead.Technical AttributesCapacity Range: 300–1200 kW Modular → primary selection parameter for matching centralized hyperscale data halls and industrial plant utility cores.Output Fidelity: 380/400/415V Selectable → ensures electrical compatibility with diverse high-voltage facility grids and high-frequency IT hardware.Battery Voltage: 360~700 VDC → selection parameter defining the energy storage window and identifying the required safety interlocks for high-voltage DC banks.Certification: IEC 62040-1/2/3, CE → provided to support procurement quality checks and ensure compliance with global safety and performance standards.
The technical framework of the Eaton 93 PR 300-1200 KVA/ KW utilizes a high-density modular aisle architecture where discrete 60 kW rectifier and inverter modules are integrated into a common high-current DC busbar chassis. The structural reasoning for this modularity is to provide "fault containment"—a failure in one module—due to IGBT breakdown or DC capacitor dry-out—can be isolated immediately, allowing the redundant modules to maintain the full facility output. measurement physics rely on high-speed synchronization buses that negotiate load sharing between modules to within ±1% accuracy. A failure in the current-sharing logic results in "circulating currents" that generate excessive heat in the busbars, decommissioning the energy efficiency of the entire site. quality consistency is managed through serialized FAT dossiers documenting waveform purity under full-load discharge. The internal chassis uses insulated bus-duct technology and reinforced structural stiffeners to manage the electromagnetic forces of high-mass energy systems, a critical standard for ensuring structural integrity under fault conditions.
Operational efficiency is achieved through the system’s "Intelligent Module Management," which optimizes the number of active modules relative to the total load to maximize conversion efficiency. functional performance centers on the unit’s support for active thermal management; if the system detects a fan failure in a power module, it triggers a diagnostic alarm and initiates a load-redistribution sequence to neighboring modules. In a real operational scenario, a failure in the phase-balancing logic leads to localized semiconductor fatigue, decommissioning the module. The 93PR series utilizes independent phase regulation to mitigate this risk. if the unit detects a significant input phase imbalance, it transitions to battery power to preserve the downstream sine-wave fidelity. maintenance procedures are simplified by the front-access design, effectively lowering the mean time to repair (MTTR). By providing detailed telemetry on harmonic rejection and load profiles, the UPS allows B2B facility managers to accurately account for energy throughput and implement predictive maintenance routines before an operational failure occur.
Designed for manufacturing cores, large data centers, and hospital central feeds, the 93PR series is configured for the logistical requirements of multimodal multi-site rollouts. Units ship in reinforced skid-mounted crates with internal steel rigid bracing and shock indicators to protect the sensitive internal processors and bus-duct connections from transport-induced damage. Failure to implement shock-monitored packaging can result in "busbar displacement," resulting in localized high-resistance joints and potential localized fires upon site commissioning. For international procurement, supply-readiness is supported through serialized test records and certificates of conformity (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize humidity-control liners and desiccant to prevent terminal oxidation during maritime transit. OEM branding and custom façade options are available, allowing facility operators to standardize their appearance across global portfolios. This high-authority approach ensures procurement teams receive verified hardware that meet the performance requirements of global manufactured utility markets.
Description provided by shakti power solutions pvt limited.
| Brand | Eaton |
|---|---|
| Model Number | 93 PR Series |
| Capacity | 300-1200 KVA/KW |
| Type | Online Double Conversion UPS |
| Phase | Single Phase |
| Efficiency | >91% |
| Battery Capacity | 100 Ah |
| Input Voltage Range | Adapted to Grid Conditions |
| Output Voltage | Stable, Clean Power Supply |
| Protection Features | Inrush Current Protection, Power Conditioning |
| Operating Environment | Harsh Indian Environmental Conditions |
| Availability | In Stock |
| MOQ | 1 Unit |
| Category | Industrial UPS Systems |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |
Common questions B2B buyers ask before sourcing Eaton 93 PR 300-1200 KVA/ KW, >80 KVA. Answers compiled from verified sellers' commercial terms and platform data.
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Post one RFQ and get quotes from all verified sellers within 48 hours. No commitment, no spam.
Post a RFQ