1/1

Delta UPS HPH Series, Three Phase 160 - 200 kVA, For Commercial

Shakti Power Solutions Pvt Limited logo
Shakti Power Solutions Pvt Limited
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler — Amritsar, Punjab, India · Replies in ~24–48 hours
FIEO Registered Export Ready
Price on request In stock
MOQ: 1 unit
Lead time: On request
GST invoice
Origin: India
Export ready
Buyer protection
Interested in this product?
Share your requirement and the seller will respond with a quote.
Comparing multiple suppliers?
Receive quotations from multiple verified suppliers and compare price & lead time.
Other buying options
Buyer-protected enquiry Seller responds in ~24–48 hours Freight & duties quoted separately
Export Snapshot
Minimum order
1 unit
HSN Code
On request
Origin
India
Lead time
On request
Port of dispatch
On request
Packaging
Standard export packaging
Shelf life / storage
As per product specification
Export markets served
Global markets
Ability to customise
As per OEM brief
Values shown are for Shakti Power Solutions Pvt Limited.
Company Shakti Power Solutions Pvt Limited
Shakti Power Solutions Pvt Limited logo
Shakti Power Solutions Pvt Limited

Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals › Diagnostic Centres & Laboratories.

FIEO Registered
View profile →
Established
Not shared
Employees
–
GST
03ABGCS0227D1ZZ
IEC code
Not shared
Export markets
Global markets
Member since
Dec 2018
Turnover
$2 MM - $5 MM
Incorporation type
On request
Product details

Material Build and Assembly Logic of the HPH 160-200 kVA Series

The technical framework of the Delta UPS HPH Series, Three Phase 160 - 200 kVA utilizes modular power cabinets integrated with bolted high-current busbars and insulated bus ducts. The structural reasoning for the rigid internal frame is to maintain mechanical stability during the massive electromagnetic forces of a short-circuit event. measurement physics rely on high-fidelity current transducers that coordinate parallel synchronization to within microseconds. A failure in the phase-matching logic results in "circulating currents" between modules—a failure mode that manifests as excessive heat in the DC bus and potential system-wide tripping. Quality consistency is managed through serialized FAT dossiers documenting waveform purity and regulation under dynamic load-step changes. The internal architecture partitions the real-time protection logic from the supervisory telemetry to prevent firmware faults from decommissioning the primary power path, a critical safety standard for live-service environments. Power stage PCBs are conformal-coated to protect against the high-humidity atmospheres common in unconditioned technical bays.

Functional Performance and Operational Efficiency in Large Data Halls

Operational efficiency is achieved through the system’s transformer-free design, which delivers peak efficiency up to 96% in normal double-conversion mode, significantly reducing the facility's cooling overhead. Functional performance centers on the unit’s support for rapid field exchange; front-accessible power modules and standardized interfaces allow for a low mean time to repair (MTTR). In a real operational scenario, a failure in the fan speed control—due to motor fatigue—leads to localized overheating of the inverter semiconductors. The HPH series utilizes integrated thermal sensors to trigger maintenance alerts before a protective shutdown occur. if the battery management system detects a capacity drop below 80% through its automated discharge testing, it triggers an end-of-life alarm for the B2B facility manager. By providing detailed telemetry on THDi and load profiles, the UPS allows for accurate energy accounting and predictive maintenance scheduling. Thermal management of the separate battery cabinets is critical; isolated ventilation paths prevent thermal coupling between the electronics and the energy storage.

Institutional Deployment and Logistical Readiness for Heavy Logistics

Suitable for centralized IT rooms, manufacturing complexes, and hospital central feeds, the HPH series is configured for the logistical requirements of multimodal multi-site rollouts. Units ship in reinforced skid-mounted crates with internal steel braces and shock-absorbing mounts to protect the high-mass cabinets from transport-induced damage. Failure to implement shock-monitored packaging can lead to "busbar displacement," resulting in localized high-resistance joints and potential fires upon site commissioning. For international procurement, supply-readiness is supported throughserialized performance test records and certificates of conformity (CE/UL). Export-ready documentation include unit configuration snapshots and material safety data sheets (MSDS) provided with each shipment to facilitate customs review and institutional asset registration. Packaging utilize vapor-barrier liners to prevent terminal oxidation during maritime transit. OEM branding and custom control mapping are available for system builders requiring branded power suites. This high-authority approach ensures procurement teams receive verified hardware that meet the performance requirements of global manufacturing markets.

Frequently Asked Questions

  • What installation clearances are mandatory? Maintain 800 mm front service clearance and 400 mm rear clearance to ensure optimal airflow and module accessibility.
  • How is the battery end-of-life determined? The system monitors internal resistance and executes scheduled load tests; replacement is recommended if capacity falls below 80% of nominal.
  • Can the system operate in unconditioned spaces? While designed for data halls, the unit supports operation between 0–40°C; however, high humidity accelerates component aging and requires regular maintenance.
  • What documentation is supplied for customs review? Shipments include serialized FAT reports, electrical safety declarations, and detailed material trace records.
  • Is parallel expansion possible in the field? Yes; the HPH architecture allows for the addition of parallel cabinets to meet increasing facility power demands.
Description provided by Shakti Power Solutions Pvt Limited.

160 - 200 kVA (Three Phase)

True Online Double-Conversion with DSP-Based Control

305~477V Wide Voltage Range

Up to 96% in ECO Mode

Supports N+X Parallel Redundancy

Built-in Manual Bypass Switch

Compact Tower Design (200x490x490 mm)

0 ~ 40 °C

5% ~ 95% (Non-Condensing)

Commercial, Industrial, IT Rooms, SMBs, Telecom, Medical, Banking

Specifications
Brand
Delta
Model Series
HPH Series
Power Rating
160 - 200 kVA
Phase Configuration
Three Phase Input - Three Phase Output
Technology
Online Double Conversion, DSP-Based
Input Voltage Range
305~477 Volts
Efficiency
Up to 96% ECO Mode
Redundancy Capability
N+X Parallel Redundancy Supported
Bypass Switch
Manual, Built-In
Operating Temperature Range
0 to 40 °C
Relative Humidity
5% to 95%, Non-Condensing
Dimensions (W x D x H)
200 x 490 x 490 mm
Weight
Not Specified
Application
Commercial Power Backup and Protection
Stock Availability
In Stock
MOQ
1 Unit
Use cases
Category
Electrical Equipment > Power Supply Equipment > Uninterruptible Power Supplies (UPS) > Industrial UPS
Primary application
Product type
Product
Logistics & handling
Lead time
On request
Packaging
As per buyer requirement
Storage condition
As recommended by supplier
Origin
India
Form
As listed by supplier
Commercials Shakti Power Solutions Pvt Limited
Minimum order
1 unit
Lead time
On request
Payment terms
As per negotiated commercial agreement
Frequently asked by buyers
Does the Delta UPS HPH Series support parallel redundancy for increased reliability?

Yes, the Delta UPS HPH Series supports N+X parallel redundancy to enhance system availability and provide seamless load sharing.

What kind of bypass feature does the UPS offer for maintenance purposes?

It includes a built-in manual bypass switch that allows maintenance or repair work without interrupting power supply to the load.

What is the input voltage range compatibility of the UPS for handling power fluctuations?

The UPS supports a wide input voltage range from 305 to 477 volts, which helps reduce battery discharge and prolong battery life.

Is the UPS suitable for harsh commercial environments with varying temperatures and humidity?

Yes, the UPS is rated to operate efficiently within 0 to 40°C temperature and 5% to 95% relative humidity (non-condensing), making it ideal for commercial settings.

Does the UPS offer any efficiency modes to reduce operational costs?

Yes, it offers an ECO mode that can achieve up to 96% efficiency, helping minimize electricity usage and operating expenses.

Question not answered? Sellers typically reply within 24–48 hours.

What similar products are available in this category?

Browse all →
bently nevada 3500/15 ac power supply module – 85-264 vac – 3500 series GST VERIFIED
bently nevada 3500/15 ac power supply module – 85-264 vac – 3500 series
Querland Industrial Automation
From $ 1,500.00
MOQ 1 NOS
b&r 5ac901.bups-01 ups battery unit GST VERIFIED
b&r 5ac901.bups-01 ups battery unit
Voltedge Trade
From $ 400.00
MOQ 1 NOS
shakti power solutions eaton 9e - 1 kva online ups without batteries, 100vac-300vac GST VERIFIED
shakti power solutions eaton 9e - 1 kva online ups without batteries, 100vac-300vac
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 unit
shakti power solutions vertiv liebert src-g series (src03ges) GST VERIFIED
shakti power solutions vertiv liebert src-g series (src03ges)
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 unit
shakti power solutions liebert gxtmt+cx 3kva (lb) GST VERIFIED
shakti power solutions liebert gxtmt+cx 3kva (lb)
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 unit
shakti power solutions single phase vertiv liebert gxt mt plus 6kva ups GST VERIFIED
shakti power solutions single phase vertiv liebert gxt mt plus 6kva ups
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 unit
shakti power solutions delta ups eh series, three phase 10/15/20 kva, for industrial GST VERIFIED
shakti power solutions delta ups eh series, three phase 10/15/20 kva, for industrial
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 unit
shakti power solutions three phase vertiv liebert s600 ups 20 kva GST VERIFIED
shakti power solutions three phase vertiv liebert s600 ups 20 kva
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 unit

More from Shakti Power Solutions Pvt Limited

View all →
shakti power solutions optiflux 6300 - electromagnetic flowmeter
shakti power solutions optiflux 6300 - electromagnetic flowmeter
Price on request
MOQ 1 unit
shakti power solutions powerflux 5030 - electromagnetic flowmeter, water
shakti power solutions powerflux 5030 - electromagnetic flowmeter, water
Price on request
MOQ 1 unit
shakti power solutions 1-3 kva eaton 9e external battery model
shakti power solutions 1-3 kva eaton 9e external battery model
Price on request
MOQ 1 unit
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
Price on request
MOQ 1 unit
shakti power solutions waterflux 3100 - electromagnetic flowmeter
shakti power solutions waterflux 3100 - electromagnetic flowmeter
Price on request
MOQ 1 unit
shakti power solutions optiflux 6050 - electromagnetic flowmeter, water
shakti power solutions optiflux 6050 - electromagnetic flowmeter, water
Price on request
MOQ 1 unit
shakti power solutions optiflux 1050 - electromagnetic flowmeter
shakti power solutions optiflux 1050 - electromagnetic flowmeter
Price on request
MOQ 1 unit
shakti power solutions af-e 400 - electromagnetic flowmeter
shakti power solutions af-e 400 - electromagnetic flowmeter
Price on request
MOQ 1 unit

More from shakti power solutions

View all →
shakti power solutions eaton 9e10 kva ups
shakti power solutions eaton 9e10 kva ups
Price on request
MOQ 1 unit
shakti power solutions eaton 93 pr 300-1200 kva/ kw, >80 kva
shakti power solutions eaton 93 pr 300-1200 kva/ kw, >80 kva
Price on request
MOQ 1 unit
shakti power solutions eaton aurora ups 1000va
shakti power solutions eaton aurora ups 1000va
Price on request
MOQ 1 unit
shakti power solutions eaton 9px ups 1000-3000w
shakti power solutions eaton 9px ups 1000-3000w
Price on request
MOQ 1 unit
shakti power solutions liebert hipulse d - industrial ac ups
shakti power solutions liebert hipulse d - industrial ac ups
Price on request
MOQ 1 unit
shakti power solutions liebert precision power center
shakti power solutions liebert precision power center
Price on request
MOQ 1 unit
shakti power solutions eaton aurora 1000va ups
shakti power solutions eaton aurora 1000va ups
Price on request
MOQ 1 unit
shakti power solutions vertiv liebert powerbank 600 rt 3x1
shakti power solutions vertiv liebert powerbank 600 rt 3x1
Price on request
MOQ 1 unit
Delta UPS HPH Series, Three Phase 160 - 200 kVA, For Commercial
Delta UPS HPH Series, Three Phase 160 - 200 kVA, For Commercial
Price on request