1/1

DRY BLOCK CALIBRATOR

Eco Mechatronics Automation logo
Eco Mechatronics Automation
Service Provider , Manufacturer, Contractor, Brand Owner, Exporter, Importer — Indore, Madhya Pradesh, India · Replies in ~24–48 hours
Export Ready
₹ 680.15 /Piece ₹ 963.55 You save ₹ 283.40 In stock
Inclusive of all taxes
MOQ: 1 Piece
Lead time: On request
GST invoice
Origin: India
Export ready
Buyer protection
Interested in this product?
Share your requirement and the seller will respond with a quote.
Comparing multiple suppliers?
Receive quotations from multiple verified suppliers and compare price & lead time.
Other buying options
Buyer-protected enquiry Seller responds in ~24–48 hours Freight & duties quoted separately
Export Snapshot
Minimum order
1 Piece
HSN Code
On request
Origin
India
Lead time
On request
Port of dispatch
On request
Packaging
Standard export packaging
Shelf life / storage
As per product specification
Export markets served
Bangladesh flag BD
Ability to customise
As per OEM brief
Values shown are for Eco Mechatronics Automation.
Company Eco Mechatronics Automation
Eco Mechatronics Automation logo
Eco Mechatronics Automation

Registered address: Indore, India.

View profile →
Established
Not shared
Employees
–
GST
23BSBPA6339L1ZV
IEC code
Not shared
Export markets
Bangladesh flag BD
Member since
Not shared
Turnover
$250,000 - $1 MM
Incorporation type
On request
Product details

Application.

In Calibration Laboratories for the Calibration of small, odd shaped sensors and thermometers.

For On-site Calibration.

Testing laboratory of RTDs abd Thermocouples.

Process Industry In-house Calibration


Features.

Fast Heating and Cooling

High Accuracy and Stability

Low weight and Compact design

Simple Operation


Technical Specifications:

Range - - 30 from Ambient to 100 Deg C @Ambient 25 Deg C

Display Resolution - 0.1 Deg C

Accuracy - + - 0.06 Deg C

Stability - +- 0.1 Deg C

Stabilization Time - 10 mnts.

Heating Time - (Ambient to 100 Deg C) - 15 mnts

Cooling Time - (Ambient to Negative Max.) - 25 mnts

Block Dia. - 22 mm

Block Immersion - 120 mm

Insertion Tube Depth - 110 mm

Power Supply - 230V AC +-2.5/50 Hz

Dimensions - (260 X 170 X 320 ( mm

Weight - 14 Kg.

Description provided by Eco Mechatronics Automation.

-30°C to 100°C

Calibration of small and odd-shaped sensors and thermometers; RTD and thermocouple testing; process industry in-house calibration

Fast heating (15 mins to 100°C), fast cooling (25 mins to -30°C)

±0.06°C

±0.1°C

0.1°C

22 mm

120 mm

110 mm

230V AC ±2.5%, 50 Hz

260 x 170 x 320 mm

14 kg

Compact, lightweight, and simple operation

Specifications
Temperature Calibration Range
-30°C to 100°C
Display Resolution
0.1°C
Accuracy
±0.06°C
Temperature Stability
±0.1°C
Stabilization Time
10 minutes
Heating Time
15 minutes (Ambient to 100°C)
Cooling Time
25 minutes (Ambient to -30°C)
Block Diameter
22 mm
Block Immersion Length
120 mm
Insertion Tube Depth
110 mm
Power Supply
230V AC ±2.5%, 50 Hz
Weight
14 kg
Dimensions (L x W x H)
260 x 170 x 320 mm
Use cases
Category
Temperature Calibration Equipment > Dry Block Calibrators
Primary application
Brand
Not specified
Product type
Product
Logistics & handling
Lead time
On request
Packaging
As per buyer requirement
Storage condition
As recommended by supplier
Origin
India
Form
As listed by supplier
Commercials Eco Mechatronics Automation
Minimum order
1 Piece
Lead time
On request
Payment terms
As per negotiated commercial agreement
Frequently asked by buyers
What is the accuracy tolerance of the dry block calibrator?

The dry block calibrator offers a high accuracy tolerance of ±0.06°C ensuring precise calibration of sensors and thermometers.

Can this calibrator be used for on-site calibration?

Yes, its low weight (14 kg), compact design, and simple operation make it well-suited for on-site calibration applications.

What range of temperature does the calibrator cover?

It covers temperatures from -30°C below ambient up to 100°C, suitable for a wide variety of temperature sensors.

How long does it take to stabilize at set temperatures?

The stabilisation time for the device is approximately 10 minutes, allowing for rapid calibration processes.

What is the size of the calibration block insertion area?

The block diameter is 22 mm with an immersion depth of 120 mm, allowing calibration of small and odd-shaped sensors.

Question not answered? Sellers typically reply within 24–48 hours.

What similar products are available in this category?

Browse all →
yokogawa ut150-rn/al/ret digital temperature controller GST VERIFIED
yokogawa ut150-rn/al/ret digital temperature controller
Voltedge Trade
From $ 350.00
MOQ 1 NOS
honeywell dc1010cr-102000-e digital temperature controller GST VERIFIED
honeywell dc1010cr-102000-e digital temperature controller
Voltedge Trade
From $ 130.00
MOQ 1 NOS
digital temperature controller GST VERIFIED
digital temperature controller
Trumech Exports Private Limited
Price on request
MOQ 1 Unit
temparature pid controller GST VERIFIED
temparature pid controller
Bose Bengal Enterprises
From $ 79.35
MOQ 1 Numbers
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications GST VERIFIED
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 Piece
shakti power solutions optitemp tra-s50 resistance (rtd) temperature assembly for use in existing thermowells or machinery GST VERIFIED
shakti power solutions optitemp tra-s50 resistance (rtd) temperature assembly for use in existing thermowells or machinery
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 Piece
shakti power solutions optitemp tca-f42 thermocouple (tc) temperature assembly for standard applications GST VERIFIED
shakti power solutions optitemp tca-f42 thermocouple (tc) temperature assembly for standard applications
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 Piece
shakti power solutions optitemp tca-s11 thermocouple (tc) temperature assembly for lower temperature applications GST VERIFIED
shakti power solutions optitemp tca-s11 thermocouple (tc) temperature assembly for lower temperature applications
Shakti Power Solutions Pvt Limited
Price on request
MOQ 1 Piece

More from Eco Mechatronics Automation

View all →
eco mechatronics tm no.6512159 testing instrument & equipment
eco mechatronics tm no.6512159 testing instrument & equipment
$ 685.82
MOQ 3 Numbers
humidity chamber
humidity chamber
$ 1,983.78
MOQ 1 Piece
eco mechatronics panel ac 250 watt to 7000 watt
eco mechatronics panel ac 250 watt to 7000 watt
$ 504.45
MOQ 1 Piece
DRY BLOCK CALIBRATOR
DRY BLOCK CALIBRATOR
₹ 680.15 /Piece