Delta 3 kVA (External Battery) INX 26ah Exide with Rack for Battery
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
Delta 3 kVA (External Battery) INX 26ah Exide with Rack for Battery – Compact Energy RackDelta 3 kVA (External Battery) INX 26ah Exide with Rack for Battery is a rack-integrated energy storage solution designed for short-to-medium autonomy in constrained IT environments. Utilizing 26 Ah Exide VRLA modules housed in a ventilated steel rack, the architecture provides a compact DC power source for Delta INX inverters. The design features keyed interconnects and integrated fusing to simplify field assembly and isolate electrical faults. Units ship with lot-specific capacity verification and serialized impedance reports, ensuring supply-readiness for edge data rooms and localized telecom nodes. Packaging utilizes reinforced crates and anti-moisture liners to preserve terminal integrity during transit. This component is essential for facilities requiring a standardized, high-density energy bank with documented performance baselines for rapid site commissioning and institutional asset management.Key FeaturesCompact 26 Ah Exide modules → provides high energy density for short-duration backup in space-constrained network aggregation points.Ventilated rack chassis → features a certified steel frame with optimized air-flow paths to prevent thermal hotspots and electrolyte dry-out.Keyed interconnect harnesses → ensures error-free polarity matching during site installation and reduces mechanical stress on battery terminals.Technical AttributesNominal Capacity: 26 Ah string → selection parameter for matching short-run autonomy targets (typically 5-15 mins at full load).Protection: Integrated DC Fusing → determines the fault isolation capability and protects the UPS from battery-side anomalies.Mounting: Rack-integrated → selection parameter for standard 19-inch equipment cabinets and localized power closets.Quality Records: Serialized Impedance Logs → provided to support string balancing and predictive maintenance planning.
The technical framework of the Delta 3 kVA (External Battery) INX 26ah Exide with Rack for Battery utilize a high-density series arrangement of sealed VRLA cells, specifically tuned for the high-current discharge profile of a 3 kVA inverter. The structural reasoning for the ventilated rack is to facilitate efficient heat rejection from the center of the battery stack; failure to maintain thermal uniformity results in "cell mismatch," where central batteries age faster than peripheral ones due to higher operating temperatures. In real operational scenarios, this thermal gradient leads to localized sulfation, reducing the string's cumulative Ampere-hour (Ah) capacity by up to 30%. Quality consistency is managed through serialized impedance reports that verify the internal resistance of each module before assembly. A failure to match impedance across the string results in "voltage tracking errors," where one battery overcharges while another remains under-capacity—a failure mode that triggers premature UPS alarms and decommissions the energy asset. The rack utilizes captive fasteners and anti-corrosion coated steel to maintain dimensional stability under the high-vibration conditions common in manufacturing plant technical rooms.
Operational efficiency is achieved through the system’s high charge acceptance rate, which allows the 26 Ah modules to recover to 90% capacity quickly after a discharge event. functional performance centers on the unit’s integrated protection suite; high-speed DC fuses are installed to isolate the battery bank from the UPS if an internal short-circuit occur. failure to implement fused isolation leads to uncontrolled energy release from the DC bus, which can result in terminal melting and arc-flash damage inside the equipment rack. In a real operational scenario, a failure in the terminal connection—due to improper torque application—leads to localized thermal gain during high-load events, manifesting as the "scorching" of internal wiring and potential system failure. The rack design supports "tool-free" visual inspection of the battery terminals, allowing technicians to verify integrity without decommissioning the load. thermal sensors can be integrated to provide telemetry to the local HMI, enabling B2B facility managers to monitor the "thermal packing density" and prevent thermal runaway during repetitive discharge tests, effectively improving the overall safety of the edge node.
Designed for small server closets, retail IT aggregation points, and localized clinical equipment, the INX 26ah rack system is configured for the logistical requirements of programmatic rollouts. Units ship in reinforced crates with anti-vibration inserts to protect the internal battery separators from mechanical damage during transport. Failure to implement shock-mitigating packaging results in "plate-to-plate shorts," which decommissioning the cells before they reach the site. For international procurement, supply-readiness is supported through serialized test certificates and wiring diagrams provided with each shipment (CE/UL). Export-ready documentation include unit configuration snapshots and material declarations (MSDS) to facilitate customs clearance and institutional asset registration. Packaging utilize moisture-barrier liners and desiccant to prevent terminal oxidation during long-haul maritime logistics. OEM branding and custom faceplate options are available for system builders requiring branded power modules. This high-authority approach ensures procurement teams receive verified, site-ready energy assets that meet the safety and performance standards of global markets, providing the logistical and technical security required for large-scale instrumentation upgrades.
Description provided by shakti power solutions pvt limited.
| UPS Power Rating | 3 kVA |
|---|---|
| Battery Type | VRLA Lead Acid |
| Battery Capacity | 150Ah |
| Additional Battery | 26Ah Exide External Battery |
| Voltage | 12 V |
| Battery Technology | Absorbent Glass Mat (AGM) |
| Material Composition | Lead calcium tin alloy in battery plates |
| Warranty Period | 1 Year |
| Country of Origin | India |
| Availability | In Stock |
| Manufacturer | Exide Industries Ltd. |
| Battery Rack | Included (External Rack) |
| Category | Electricals > Power Backup > UPS Systems > UPS with External Battery |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |
Common questions B2B buyers ask before sourcing Delta 3 kVA (External Battery) INX 26ah Exide with Rack for Battery. Answers compiled from verified sellers' commercial terms and platform data.
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Post one RFQ and get quotes from all verified sellers within 48 hours. No commitment, no spam.
Post a RFQ