Delta 2 kVA INX (Internal Battery)
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
Delta 2 kVA INX UPS – Internal Battery ModuleDelta 2 kVA INX is a compact online double-conversion UPS module featuring an integrated internal battery bank for single-phase critical loads. Utilizing a high-density chassis, the unit provides continuous conditioned power with zero transfer time for small IT racks and medical point-of-care devices. The architecture emphasizes a minimal footprint and front-access service trays to reduce maintenance duration. Units are prepared for large-volume distribution, shipping palletized with vibration dampers and shock-rated trays. Supply-readiness is managed through lot-based serialization and factory test reports, addressing the requirements of facility engineers seeking verified, site-ready energy assets for remote communication nodes and retail servers requiring documented state-of-health (SoH) metrics for institutional asset registration. Packaging includes moisture-barrier wrapping for maritime logistics.Key FeaturesIntegrated sealed battery bank → maximizes equipment room area by housing energy storage within the primary UPS cabinet, eliminating the requirement for external battery racks.Double-conversion online logic → provides complete isolation of the load from grid sags, surges, and frequency fluctuations, delivering a regulated sine-wave output at all times.Front-access service architecture → features removable battery trays and power modules to facilitate rapid field replacement and minimize mean time to repair (MTTR).Technical AttributesRated Power: 2 kVA / 1.8 kW → primary selection parameter for matching localized sensor arrays and IT workstation loads.Internal Energy Storage: Sealed VRLA → determines the primary autonomy window for graceful system shutdowns and identifies ventilation requirements.Cooling: Sensor-regulated Forced-Air → features redundant fans and filtered air paths to maintain thermal limits under continuous operation.Traceability: Serialized Unit FAT → provided per unit to support procurement quality control and site acceptance testing.
The technical framework of the Delta 2 kVA INX (Internal Battery) utilize a high-fidelity power stage where the rectifier, inverter, and energy storage modules are integrated within a single high-stiffness metallic cabinet. The structural reasoning for the internal battery trays is to maintain a "tight electrical coupling"—by minimizing the length of the DC bus cables, the unit reduces electromagnetic interference (EMI) and localized impedance sags. measurement physics rely on high-speed transducers that monitor the state-of-charge (SoC) and cell-level voltage balance. A failure in the battery charging circuit—due to firmware drift or localized surge damage—leads to "overcharge heating," manifesting as container swelling and potential fire hazards. Quality consistency is managed through serialized test reports documenting battery discharge curves under full load. The internal layout utilizes segregated thermal channels to protect the high-frequency power semiconductors from the heat generated by the energy storage bank during discharge events, ensuring the UPS serves as a stable energy asset.
Operational efficiency is achieved through the system’s high-frequency conversion logic, which delivers peak efficiency even at partial loads, an essential operational standard for medical point-of-care workstations. Functional performance centers on the unit’s thermal stability; if the unit detects a fan motor failure through its monitoring interface, it triggers a diagnostic alarm and initiates a fail-safe mode to prevent IGBT rupture. In a real operational scenario, a failure in the moisture seal—due to incorrect installation in unconditioned telecom closets—leads to "surface tracking" on the PCBA, effectively decommissioning the control logic. The INX series utilizes conformally coated electronics to mitigate this risk. if the unit detects a battery end-of-life condition through its automated impedance monitoring, it provides a preemptive maintenance alert via its digital interface. maintenance procedures are simplified by the front-access design, effectively lowering the mean time to repair (MTTR) by enabling technicians to swap battery trays without Removing the UPS from the equipment rack. By providing a stable and traceable environmental signal, the unit improves the situational awareness of the facility management team.
Designed for small server rooms, network closets, and medical workstations, the 2 kVA INX is configured for the logistical requirements of project-scale procurement. Units ship on palletized skids with vibration-damping inner trays and shock indicators to protect the sensitive internal inductors and electrodes during transit. Failure to implement shock-mitigating packaging can lead to "transformer humming" or loose joints in the battery-to-terminal assembly, manifesting as intermittent power loss upon site arrival. For international procurement, supply-readiness is supported through lot-based technical specifications and factory test certificates (ISO/CE). Export-ready documentation include unit configuration snapshots and installation checklists provided with each shipment to facilitate institutional asset registration. Packaging utilize moisture-barrier covers and desiccants to prevent terminal oxidation during maritime freight. OEM branding and custom firmware configurations are available, allowing buyers to standardize their fleet appearance. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global manufacturing markets.
Description provided by shakti power solutions pvt limited.
| Brand | Vertiv Liebert |
|---|---|
| Model Name/Number | Liebert RG |
| Capacity Range | 40 kVA - 250 kVA (General Series Range) |
| Applicable Model Capacity | 2 kVA (Specific Product) |
| Phase | 3:3 |
| Weight | Not Specified for Delta 2 kVA INX |
| Warranty | 1 Year |
| Operating Temperature | 0 to 40°C |
| Form Factor | Tower |
| Frequency | 50/60 Hz |
| Internal Battery | Yes |
| Audible Noise | Suitable for Industrial Applications |
| Category | Industrial UPS Systems |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |
Common questions B2B buyers ask before sourcing Delta 2 kVA INX (Internal Battery). Answers compiled from verified sellers' commercial terms and platform data.
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Post one RFQ and get quotes from all verified sellers within 48 hours. No commitment, no spam.
Post a RFQ