Vertiv Liebert PDX PX025
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
Liebert PDX PX025 precision air conditioner – Modular Air-Cooled UnitVertiv Liebert PDX PX025 is a modular air-cooled precision cooling system engineered for data halls and equipment rooms requiring scalable capacity and high availability. Utilizing an online modular architecture, the PX025 integrates accessible control modules and independent refrigeration stages to support staged facility deployment. The design features integrated diagnostics and trend logging to facilitate predictive maintenance planning and optimize compressor runtime. Units are offered for contract and large-volume supply, shipping on palletized skids with consolidated technical dossiers. Supply-readiness is managed through factory acceptance testing (FAT) per serial number, addressing the requirements of data center operators seeking documented performance for site acceptance testing and facility energy accounting. Packaging includes protective crating to ensure the structural integrity of the sensitive fan and control assemblies during international logistics.Key FeaturesModular PX architecture → allows for incremental capacity growth without footprint changes, enabling facility managers to scale cooling alongside IT load evolution.Accessible control electronics → features an isolated control enclosure to simplify on-site commissioning, firmware updates, and diagnostic retrieval without disrupting service.Integrated trend diagnostics → provides real-time event histories and fault code reporting to support condition-based maintenance and maximize unit uptime.Technical AttributesDesign Principle: Modular Air-Cooled → selection parameter for sites requiring independent thermal management without centralized chilled-water.Supply Standard: Three-Phase Interface → ensures compatibility with standardized industrial power distribution and generator transfer arrays.Traceability: Serial-level FAT → provided per unit to validate thermal throughput and electrical safety before warranty activation.Cooling Strategy: Staged Modulation → determines the system’s ability to maintain tight setpoints under variable equipment heat loads.
The technical framework of the Vertiv Liebert PDX PX025 utilizes a modular chassis with segregated compartments for refrigeration, air-handling, and control electronics. The structural reasoning for this segregation is to provide "Safe-State Serviceability"; by isolating the high-voltage power components from the low-voltage logic, the system allows for control adjustments while the refrigeration cycle remains active. measurement physics rely on high-sampling-rate transducers that monitor evaporator superheat and compressor discharge pressure. A failure in the expansion valve logic—due to localized EMI or sensor drift—leads to "liquid carry-over," where unvaporized refrigerant enters the compressor, resulting in catastrophic mechanical failure and decommissioning of the cooling module. Quality consistency is managed through serialized dimensional inspections and structural stiffeners that minimize vibration transfer from fans to electronic assemblies. The internal frame utilizes high-grade insulation to prevent localized "cabinet sweating" in high-humidity equipment rooms, a critical standard for protecting adjacent IT racks from moisture-induced short-circuits.
Operational efficiency is achieved through the system’s staged modulation algorithms, which balance compressor runtime against measured room loads to minimize start-stop wear. functional performance centers on the unit’s thermal stability; if the system detects a fan failure through its monitoring interface, it triggers a diagnostic alarm and initiates a load-redistribution sequence to neighboring modules. In a real operational scenario, a failure in the static pressure sensor leads to "airflow starvation," resulting in localized hotspots and potential server shutdowns. The PX025 utilizes redundant fan modules to mitigate this risk. if the unit detects a power supply phase imbalance, the internal safety interlocks execute a protective shutdown to prevent compressor motor winding damage—effectively lowering the mean time to repair (MTTR) by identifying the fault source immediately. By providing detailed telemetry on thermal trends and load profiles, the unit allows B2B facility managers to accurately account for energy throughput and implement predictive maintenance routines before an operational failure occur.
Suitable for data center pods, remote technical rooms, and industrial enclosures, the PX025 is configured for the logistical requirements of programmatic multi-site procurement. Units ship in reinforced pallets with internal rigid bracing and moisture-barrier film to protect the sensitive control boards and copper manifolds from maritime and road freight vibration. Failure to implement shock-mitigating packaging can result in "joint fatigue," leading to refrigerant leaks that manifest weeks after installation. For international procurement, supply-readiness is supported through lot-specific technical dossiers and factory acceptance reports (CE/UL). Export-ready documentation include wiring schematics, control parameter sheets, and commissioning checklists provided with each shipment to facilitate institutional asset registration. OEM labeling and custom firmware configurations are available, allowing facility operators to standardize their appearance across global portfolios. This high-authority approach ensures procurement teams receive verified hardware that meet the performance and safety requirements of global markets, providing the technical transparency required for large-scale infrastructure tracking.
Description provided by shakti power solutions pvt limited.
| Brand | FlaktGroup |
|---|---|
| Application | Industrial Use |
| Gross Total Capacity | 10.1 kW |
| Air Volume | 2,993 m³/h |
| Air Intake Temperature | 24°C |
| Available Unit Sizes | 600 x 600 mm to 880 x 3380 mm |
| Cooling Types | Direct Expansion (DX), Chilled Water (CW), CombiCool, FreeCool |
| Air Direction | Upflow and Downflow |
| Control Software | DENCONET |
| BMS Interface | Available |
| Optional Features | Humidity control and reheating |
| Category | Industrial Precision Air Conditioning Units |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |
Common questions B2B buyers ask before sourcing Vertiv Liebert PDX PX025. Answers compiled from verified sellers' commercial terms and platform data.
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Verified
Post one RFQ and get quotes from all verified sellers within 48 hours. No commitment, no spam.
Post a RFQ