1/6
Export Ready

Phase monitoring relay

Sold by om prakash agrahari · Distributor, Exporter, Wholesaler · Kanpur Nagar, Uttar Pradesh, India

Price
₹ 169.47 /Unit
In stock
MRP ₹ 248.94
Inclusive of all taxes
You Save: ₹ 79.47
Minimum order: 1 Unit

Export Snapshot

MOQ
1 Unit
Lead time
On request
Packaging
Standard export packaging
Shelf life / longevity
As per product specification
HS Code
85364900
Origin
India
Port of dispatch
On request
Export markets served
Global markets
Values shown are for om prakash agrahari.
Compliance & Certifications
Suitable for

Importers · Distributors · Wholesalers

Know your supplier

om prakash agrahari is a Distributor, Exporter, Wholesaler based in Kanpur Nagar Uttar Pradesh India.

Kanpur Nagar Dispatch on request Verified seller
om prakash agrahari logo

Distributor, Exporter, Wholesaler · Kanpur Nagar, Uttar Pradesh, India

We are supplier of electrical needs for industrial applications delivering across globe . We offer high quality products of almost all reputed brands. To place requirement please contact on following Info@b2celectricals.com ssenterprises091957@gmail.com +91 9453283150 +91 8618466473/ +91 9638042900 +91-9453283150 www.b2celectricals.com

Registered address: Kanpur Nagar, India. Industry: Tools, Machinery & Components > Heavy Electrical Equipment.

Established
2022
Employees
1–10
GST
09DMDPA7689K1ZG
IEC code
Not shared
Export markets
Global markets
GlobalLinker Member Since
Feb 2025
Turnover
2500001 - 10000000.
Incorporation Type
On request
Product details

What are the specifications of this product?

Overview

The CM-PAS.41S relay is from the CM three-phase monitors range. This relay operates  with a rated control supply voltage / three-phase measuring voltage of 300-500 V AC  and has a 2 c/o output with contacts rated at 250 V / 4 A. The CM-PAS.41S monitors  the phase parameters phase failure, phase sequence and phase unbalance. An ON delay is adjustable over a range of instantaneous to 30 s (0, 0.1-30 s). A sealable  transparent cover for protection against unauthorized changes is available as  accessory. The device offers screw connection technology with double-chamber cage  connection terminals.

Product Description

 Technical

 Phase failure detection

Phase sequence monitoring

Phase unbalance detection

 Function

 (L-L) 300 ... 500 V AC Measuring Range

 200 ms start-up delay

0 s or 0.1 ... 30 s tripping delay (ON)

 Time Range

 (L-L) 300 ... 500 V AC Rated Control Supply

 Voltage (Us)

 Supply Circuit 50/60 Hz Rated Frequency (f)

 2 c/o (SPDT) contacts Output

 Screw Terminals Terminal Type

 (230 V) 4 A Rated Operational

 Current AC-12 (Ie)

 (230 V) 3 A Rated Operational

 Current AC-15 (Ie)

 (24 V) 4 A Rated Operational

 Current DC-12 (Ie)

 (24 V) 2 A Rated Operational

 Current DC-13 (Ie)

 24 V

10 mA

 Minimum Switching

 Capacity

 Input Circuit 6 kV

Output Circuit 4 kV

 Rated Impulse

 Withstand Voltage (Uimp

 )

 Input Circuit / Output Circuit 600 V

Output Circuit 1 / Output Circuit 2 300 V

 Rated Insulation Voltage

 (Ui)

 Housing IP50

Terminals IP20

 Degree of Protection

 III Overvoltage Category

 3 Pollution Degree

 Output Circuit NC - F Type Fuses 6 A

Output Circuit NO - F Type Fuses 10 A

 Short-Circuit Protective

 Devices

 AC-12 100000 cycle Electrical Durability

 30000000 cycle Mechanical Durability

 Flexible with Ferrule 1x 0.5 ... 2.5 mm²

Flexible with Ferrule 2x 0.5 ... 1.5 mm²

Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²

Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²

Flexible 1x 0.5 ... 2.5 mm²

Flexible 2x 0.5 ... 1.5 mm²

Rigid 1x 0.5 ... 4 mm²

Rigid 2x 0.5 ... 2.5 mm²

 Connecting Capacity

 0.6 ... 0.8 N·m Tightening Torque

 8 mm Wire Stripping Length

 0.8 x 4

4.5

Pozidriv 1

 Recommended Screw

 Driver

 2 CM-PAS.41S

 © 2023 ABB. All rights reserved. Subject to change without notice 2023/10/30

1 ... 6 Mounting Position

 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715

TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

 Mounting on DIN Rail

 CAN/CSA C22.2 No.14

IEC/EN 63000

IEC/EN 60255-27

IEC/EN 61000-6-2

IEC/EN 61000-6-3

UL 508

 Standards

 Technical UL/CSA

 Output Circuit 300 V AC Maximum Operating

 Voltage UL/CSA

 B300 Contact Rating UL/CSA

 Flexible 1x 18-14 AWG

Flexible 2x 18-16 AWG

Rigid 1x 20-12 AWG

Rigid 2x 20-14 AWG

 Connecting Capacity

 UL/CSA

 7.08 in·lb Tightening Torque

 UL/CSA

 B300 Pilot Duty UL/CSA

 V-0 Flammability According

 to UL94

Description provided by om prakash agrahari.

Specifications

Operating Voltage Range 300-500 V AC (L-L)
Start-Up Delay 200 ms
Tripping Delay (ON) 0 s or adjustable 0.1 to 30 s
Rated Frequency 50/60 Hz
Output Contact Current Ratings 4 A AC-12 (230 V), 3 A AC-15 (230 V), 4 A AC-15 (24 V), 2 A DC-12 (24 V), 10 mA DC-13 (24 V minimum)
Rated Insulation Voltage (Ui) 300 V AC
Rated Impulse Withstand Voltage (Uimp) 6 kV input, 4 kV output
Terminal Type Screw terminals with double-chamber cage connection
Connecting Capacity Flexible and rigid cables ranging from 0.5 to 4 mm²
Tightening Torque 0.6 - 0.8 N·m (8 mm wire stripping length)
Mounting Position Any
Degree of Pollution 3
Overvoltage Category III
Flammability Rating V-0 according to UL94
Dimensions & Weight Fits standard 35mm DIN rails; weight data available on request

Use cases

Category electrical equipment and supplies > electrical controls and components > relays
Primary application Wholesale, distribution, and international sourcing
Brand abb
Product type Product

Logistics & handling

Lead time On request
Packaging As per buyer requirement
Storage condition As recommended by supplier
Origin India
Form As listed by supplier

Commercials (this seller)

Minimum order 1 Unit
Lead time On request
Payment terms As per negotiated commercial agreement.
Checkout type enquiry
Buyer questions

Frequently asked by buyers

Common questions B2B buyers ask before sourcing Phase monitoring relay. Answers compiled from verified sellers' commercial terms and platform data.

Q: What is the adjustable ON delay range on the CM-PAS.41S and how does it benefit operations?
A: The ON delay on the CM-PAS.41S is adjustable from instantaneous to 30 seconds (0.1 to 30 s), allowing customization of the relay's trip response time to avoid nuisance tripping from transient voltage fluctuations and ensuring stable operation in varying industrial environments.
Q: Can the CM-PAS.41S monitor all three phase parameters necessary for comprehensive three-phase protection?
A: Yes, the CM-PAS.41S simultaneously monitors phase failure, phase sequence, and phase unbalance, providing thorough protection and detection capabilities for three-phase electrical systems.
Q: What types of wiring connections are supported by the CM-PAS.41S relay terminals?
A: The relay uses screw terminals with double-chamber cage connection technology designed for flexible, flexible with ferrule, and rigid conductors ranging from 0.5 to 4 mm² cross-section, ensuring secure and versatile wiring options.
Q: Is the CM-PAS.41S suitable for mounting on standard DIN rails?
A: Yes, it is designed for easy mounting on TH35-15 and TH35-7.5 standard DIN rails compliant with IEC 60715, facilitating straightforward integration into existing electrical enclosures.
Q: Does the CM-PAS.41S relay provide any tamper protection features?
A: An optional sealable transparent cover is available as an accessory, which protects against unauthorized adjustments, enhancing the security of relay settings in critical applications.
Question not answered? Ask sellers directly — typical response within 4 hours.