1/5

ABB make contactor_A260-30

Ss Enterprises logo
Ss Enterprises
Distributor, Exporter, Wholesaler — Kanpur Nagar, Uttar Pradesh, India · Replies in ~24–48 hours
Export Ready
₹ 368.42 /Unit ₹ 871.96 You save ₹ 503.54 In stock
Inclusive of all taxes
MOQ: 1 Unit
Lead time: On request
GST invoice
Origin: India
Export ready
Buyer protection
Interested in this product?
Share your requirement and the seller will respond with a quote.
Comparing multiple suppliers?
Receive quotations from multiple verified suppliers and compare price & lead time.
Other buying options
Buyer-protected enquiry Seller responds in ~24–48 hours Freight & duties quoted separately
Export Snapshot
Minimum order
1 Unit
HSN Code
8536
Origin
India
Lead time
On request
Port of dispatch
On request
Packaging
Standard export packaging
Shelf life / storage
As per product specification
Export markets served
Global markets
Ability to customise
As per OEM brief
Values shown are for Ss Enterprises.
Company Ss Enterprises
Ss Enterprises logo
Ss Enterprises

We are supplier of electrical needs for industrial applications delivering across globe . We offer high quality products of almost all reputed brands. To place requirement please contact on following Info@b2celectricals.com ssenterprises091957@gmail.com +91 9453283150 +91 8618466473/ +91 9638042900 +91-9453283150 www.b2celectricals.com

Registered address: Kanpur Nagar, India. Industry: Tools, Machinery & Components › Heavy Electrical Equipment.

View profile →
Established
2022
Employees
1–10
GST
09DMDPA7689K1ZG
IEC code
Not shared
Export markets
Global markets
Member since
Feb 2025
Turnover
$50,000 - $250,000
Incorporation type
On request
Product details

 Technical

 3 Number of Main

 Contacts NO

 0 Number of Main

 Contacts NC

 1 Number of Auxiliary

 Contacts NO

 1 Number of Auxiliary

 Contacts NC

 Main Circuit 690 V Rated Operational

 Voltage

 Main Circuit 50 / 60 Hz Rated Frequency (f)

 acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 400 A Conventional Free-air

 Thermal Current (Ith)

 (690 V) 40 °C 400 A

(690 V) 55 °C 350 A

(690 V) 70 °C 290 A

 Rated Operational

 Current AC-1 (Ie)

 (415 V) 55 °C 260 A

(440 V) 55 °C 240 A

(500 V) 55 °C 240 A

(690 V) 55 °C 220 A

(380 / 400 V) 55 °C 260 A

(220 / 230 / 240 V) 55 °C 260

 Rated Operational

 Current AC-3 (Ie)

 (415 V) 140 kW

(440 V) 140 kW

(500 V) 180 kW

(690 V) 200 kW

(380 / 400 V) 140 kW

(220 / 230 / 240 V) 80 kW

 Rated Operational Power

 AC-3 (Pe)

 8 x Ie AC-3 Rated Breaking Capacity

 AC-3

 10 x Ie AC-3 Rated Making Capacity

 AC-3

 gG Type Fuses 500 A Short-Circuit Protective

 Devices

 at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A

 Rated Short-time

 Withstand Current Low

 Voltage (Icw)

 cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2600 A

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2400 A

 Maximum Breaking

 Capacity

 (AC-1) 300 cycles per hour

(AC-2 / AC-4) 150 cycles per hour

(AC-3) 300 cycles per hour

 Maximum Electrical

 Switching Frequency

 (110 V) 2 Poles in Series, 40 °C 400 A

(220 V) 3 Poles in Series, 40 °C 400 A

 Rated Operational

 Current DC-1 (Ie)

 2/5 A260-30-11-80

 © 2024 ABB. All rights reserved. Subject to change without notice 2024/09/07

A260-30-11-80

 3/5

 Rated Operational

 Current DC-3 (Ie)

 (110 V) 2 Poles in Series, 40 °C 400 A

(220 V) 3 Poles in Series, 40 °C 400 A

 Rated Operational

 Current DC-5 (Ie)

 (110 V) 2 Poles in Series, 40 °C 400 A

(220 V) 3 Poles in Series, 40 °C 400 A

 Rated Insulation Voltage

 (Ui)

 acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V

acc. to UL/CSA 600 V

 Rated Impulse

 Withstand Voltage (Uimp

 )

 Main Circuit 8 kV

 Mechanical Durability

 5 million

 Maximum Mechanical

 Switching Frequency

 3600 cycles per hour

 Coil Operating Limits

 (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)

 Rated Control Circuit

 Voltage (Uc)

 50 Hz 220 ... 230 V

60 Hz 230 ... 240 V

 Coil Consumption

 Holding at Max. Rated Control Circuit Voltage 50 Hz 60 V·A

Holding at Max. Rated Control Circuit Voltage 60 Hz 65 V·A

Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1350 V·A

Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1550 V·A

 Operate Time

 Between Coil De-energization and NC Contact Closing 7 ... 13 ms

Between Coil De-energization and NO Contact Opening 10 ... 16 ms

Between Coil Energization and NC Contact Opening 12 ... 30 ms

Between Coil Energization and NO Contact Closing 17 ... 35 ms

 Connecting Capacity

 Main Circuit

 Bar 32 mm²

Rigid Al-Cable 2 x 95 ... 120 mm²

Rigid Cu-Cable 16 ... 240 mm²

 Connecting Capacity

 Auxiliary Circuit

 Flexible with Ferrule 2x 0.75 ... 2.5 mm²

Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²

Flexible 2x0.75 ... 2.5 mm²

Solid 2 x 1 ... 4 mm²

Stranded 2 x 1 .... 4 mm²

 Degree of Protection

 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20

 Connecting Terminals

 (delivered in open

 position) Main Poles

 Flat type c/w screws and bolts

 Terminal Type

 Main Circuit: Bars

 Technical UL/CSA

 NEMA Size

 5

 Maximum Operating

 Voltage UL/CSA

 Main Circuit 600 V

 General Use Rating

 UL/CSA

 (600 V AC) 350 A

 Horsepower Rating

 UL/CSA

 (200 V AC) Three Phase 75 hp

(208 V AC) Three Phase 75 hp

(220 ... 240 V AC) Three Phase 100 hp

(440 ... 480 V AC) Three Phase 200 hp

(550 ... 600 V AC) Three Phase 250 hp

Description provided by Ss Enterprises.

3

1

1

Up to 690 V AC

Up to 400 A

Up to 200 kW

400 A at 40 °C

5 million operations

24 to 690 V AC, 50/60 Hz

1000 V

8 kV

IP00 (main terminals), IP20 (coil terminals)

Up to 3500 A

50/60 Hz

Up to 2.5 mm²

Specifications
Main Circuit Rated Voltage
690 V
Rated Frequency
50/60 Hz
Rated Operating Current (AC-3, 690 V)
220 A
Rated Operating Current (AC-3, 415 V)
260 A
Rated Operational Power AC-3 (690 V)
200 kW
Rated Making Capacity (AC-3)
10 x Ie
Rated Breaking Capacity (AC-3)
8 x Ie
Short Circuit Protective Device Rating
500 A gG type fuses
Thermal Current (Ith) at 55 °C
350 A
Mechanical Switching Frequency
3600 cycles/hour
Electrical Switching Frequency
300 cycles/hour (AC-3)
Coil Consumption (Holding at Max Rated Voltage)
50-65 V·A
Operating Temperature Range
Up to 70 °C
Connecting Capacity Main Circuit (Cu Cable)
16 – 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible cables 0.75 – 2.5 mm²
Mechanical Durability
5 million operations
UL/CSA Rated Voltage (Main Circuit)
600 V
UL/CSA Horsepower Rating at 480 V AC
200 hp
Use cases
Category
electrical equipment and supplies > medium and high voltage products > mv and hv voltage contactors
Primary application
Brand
abb
Product type
Product
Logistics & handling
Lead time
On request
Packaging
As per buyer requirement
Storage condition
As recommended by supplier
Origin
India
Form
As listed by supplier
Commercials Ss Enterprises
Minimum order
1 Unit
Lead time
On request
Payment terms
As per negotiated commercial agreement
Frequently asked by buyers
What makes the ABB A260-30 suitable for motor starting applications up to 200 kW?

The ABB A260-30 contactor supports rated operational power up to 200 kW at 690 V AC-3, combined with a high conventional free-air thermal current of 400 A and rated making/breaking capacities, which makes it ideal for controlling and protecting heavy motors during start-up.

How does the A260-30 handle short-circuit protection in industrial environments?

It can be used with 500 A gG type fuses and features a rated breaking capacity and short-time withstand currents up to 3500 A under specified conditions, ensuring high level short-circuit protection compliant with IEC standards.

What are the coil voltage options and their implications for various industrial control systems?

The coil operates with control voltages ranging from 24 to 690 V AC at 50/60 Hz, enabling integration with diverse industrial control systems and voltage ranges for flexible application.

What terminal connection options are available for wiring with the ABB A260-30 contactor?

The main circuit supports bar connections for rigid cables with a capacity up to 240 mm² for copper and aluminum cables, and auxiliary circuits support flexible cables with ferrules from 0.75 to 2.5 mm², providing versatile wiring options.

How does the mechanical durability of the A260-30 support industrial usage?

With a mechanical durability rating of 5 million operations and a maximum mechanical switching frequency of 3600 cycles per hour, the A260-30 is designed to withstand the demands of continuous industrial use.

Question not answered? Sellers typically reply within 24–48 hours.

What similar products are available in this category?

Browse all →
l&t mnx 40a contactor GST VERIFIED
l&t mnx 40a contactor
Sellomas
Price on request
MOQ 1 Numbers
l & t mnx 12 contactor GST VERIFIED
l & t mnx 12 contactor
Sellomas
Price on request
MOQ 1 Numbers
l&t 3 pole mnx 9 contactor GST VERIFIED
l&t 3 pole mnx 9 contactor
Sellomas
Price on request
MOQ 1 Numbers
contactors
contactors
Prime Syndicate
Price on request
MOQ 1 Centimetre
contactor GST VERIFIED
contactor
Mahavir Exports
Price on request
MOQ 1 Unit
four pole contactor GST VERIFIED
four pole contactor
Mahavir Exports
Price on request
MOQ 1 Unit
abb make contactor_eh300_sk826401 GST VERIFIED
abb make contactor_eh300_sk826401
Om Prakash Agrahari
From $ 402.42
MOQ 1 Unit
eaton moeller contactor dilm150(rac240)
eaton moeller contactor dilm150(rac240)
Jatin Gaur
Price on request
MOQ 1 Centimetre

More from Ss Enterprises

View all →
proton make annunciator panel
proton make annunciator panel
$ 175.71
MOQ 1 Unit
abb phase monitoring relay
abb phase monitoring relay
$ 169.47
MOQ 1 Unit

More from abb

View all →
abb low voltage switch gear
abb low voltage switch gear
Price on request
MOQ 1 Centimetre
ABB make contactor_A260-30
ABB make contactor_A260-30
₹ 368.42 /Unit