1/6
FIEO Registered FIEO Registered Export Ready

SELEC XT5042 DUAL SET POINT, UNIVERSAL POWER SUPPLY

Sold by a s enterprises · Manufacturer, Contractor, Brand Owner, Distributor, Exporter, Importer, Wholesaler, Women Entrepreneur · Surat, Gujarat, India

Price
Price on request
In stock
Minimum order: 1 Piece

Export Snapshot

MOQ
1 Piece
Lead time
On request
Packaging
Standard export packaging
Shelf life / longevity
As per product specification
HS Code
85364900
Origin
India
Port of dispatch
On request
Export markets served
Global markets
Values shown are for a s enterprises.
Compliance & Certifications
FIEO Registered FIEO Registered
Suitable for

Importers · Distributors · Wholesalers

Know your supplier

a s enterprises is a Manufacturer, Contractor, Brand Owner, Distributor, Exporter, Importer, Wholesaler, Women Entrepreneur based in Surat Gujarat India.

Surat Dispatch on request FIEO member
a s enterprises logo

Manufacturer, Contractor, Brand Owner, Distributor, Exporter, Importer, Wholesaler, Women Entrepreneur · Surat, Gujarat, India

Registered address: Surat, India.

Established
Not shared
Employees
GST
24CIKPS6663M1ZG
IEC code
Not shared
Export markets
Global markets
GlobalLinker Member Since
Not shared
Turnover
Incorporation Type
On request
Product details

What are the specifications of this product?

Overview

7 FUNCTIONS, PULSE START, DUAL SET POINT, UNIVERSAL POWER SUPPLY Product: XT5042 7 Functions, 9 Time Ranges 4 Digits, 7 segment LED Dual Display LED Status Indications : Relay Status, Seconds, Minutes, Hours Dual Set Point Batch Function

Product Description

Brief Specifications

Display Type 7 Segment LED, Dual Display

Display Configuration 4 + 4 Digits

Output Contact 2 C/O SPST


Feature Memory Retention

Range 99.99 / 999.9 / 9999sec, 99.59min:sec / 999.9 / 9999min, 99.59hr:min / 999.9hr / 9999hr

Operating Modes Interval, ON Delay, Cyclic ON first, Cyclic OFF First, Forward - Pause - Reverse, Instantaneous + Delayed 


Reset Front, Remote, Power Interruption

Counting Direction Up / Down

Supply Voltage 85 to 270V AC , 24V AC / DC


Description provided by a s enterprises.

Specifications

Display Configuration Dual 4-digit 7-segment LED
Time Ranges From 99.99 sec to 9999 hr with various time formats (seconds, minutes, hours)
Operating Modes Interval, ON Delay, Cyclic ON First, Cyclic OFF First, Forward-Pause-Reverse, Instantaneous + Delayed
Reset Methods Front panel, remote input, power interruption
Output Type 2 Change Over (C/O) SPST relay outputs
Power Requirements Universal supply voltage 85-270V AC and 24V AC/DC
Dimensions 48mm x 48mm panel mount size
LED Status Indications Relay status, seconds, minutes, hours
Batch Function Supports batch counting and programmable batch control
Certification Certified to CE and UL standards

Use cases

Category electrical equipment and supplies > electrical supplies > industrial power supplies
Primary application Wholesale, distribution, and international sourcing
Brand a s enterprises
Product type Product

Logistics & handling

Lead time On request
Packaging As per buyer requirement
Storage condition As recommended by supplier
Origin India
Form As listed by supplier

Commercials (this seller)

Minimum order 1 Piece
Lead time On request
Payment terms As per negotiated commercial agreement.
Checkout type enquiry
Buyer questions

Frequently asked by buyers

Common questions B2B buyers ask before sourcing SELEC XT5042 DUAL SET POINT, UNIVERSAL POWER SUPPLY. Answers compiled from verified sellers' commercial terms and platform data.

Q: Can the SELEC XT5042 maintain settings during power failures?
A: Yes, the XT5042 features memory retention that saves its timing and batch settings even during power interruptions, ensuring uninterrupted automation control.
Q: What timing modes does the XT5042 support for complex industrial applications?
A: The XT5042 supports 7 operating modes including interval timing, ON delay, cyclic ON first, cyclic OFF first, forward-pause-reverse cycles, and combined instantaneous plus delayed functions, enabling flexible control sequences.
Q: How does the dual set point functionality enhance process control?
A: Dual set points allow two independent timing thresholds within a single device, enabling control of multiple stages or outputs simultaneously, which reduces the need for multiple timers.
Q: Is the power supply compatible with different industrial environments?
A: Yes, the universal power supply input accepts 85 to 270V AC and 24V AC/DC, making it suitable for a wide variety of industrial power environments globally.
Q: What options are available for resetting the timer batch counts?
A: Batch counts and timing sequences can be reset from the front panel, through remote input signals, or automatically upon power interruption, allowing flexible integration with industrial processes.
Question not answered? Ask sellers directly — typical response within 4 hours.
SELEC XT5042 DUAL SET POINT, UNIVERSAL POWER SUPPLY
SELEC XT5042 DUAL SET POINT, UNIVERSAL POWER SUPPLY
Price on request · MOQ 1Piece