1/5
Export Ready

Electrical insulators

Sold by make sure engineers · Service Provider , Manufacturer, Contractor, Exporter, Wholesaler · Vadodara, Gujarat, India

Price
₹ 3.74 /unit
In stock
Inclusive of all taxes
Minimum order: 1 unit

Export Snapshot

MOQ
1 unit
Lead time
On request
Packaging
Standard export packaging
Shelf life / longevity
As per product specification
HS Code
854620
Origin
India
Port of dispatch
On request
Export markets served
Global markets
Values shown are for make sure engineers.
Compliance & Certifications
Suitable for

Importers · Distributors · Wholesalers

Know your supplier

make sure engineers is a Service Provider , Manufacturer, Contractor, Exporter, Wholesaler based in Vadodara Gujarat India.

Vadodara Dispatch on request Verified seller
make sure engineers logo

Service Provider , Manufacturer, Contractor, Exporter, Wholesaler · Vadodara, Gujarat, India

MakeSure Engineers is a trusted manufacturer and supplier of electrical & power distribution/transmission materials such as Electrical Insulators, Transformer Maintenance Material, Cables & Conductors, Earthing material, Cable accessories (Cable lugs, trays, etc). AB Switches, DO Fuses, Electrical safety items, (Gloves, helmet, etc), and Strain Hardware Fittings, meeting global standards of quality and safety.

Registered address: Vadodara, India. Industry: Electricals & Electronics > Electrical Equipment & Parts.

Established
2002
Employees
31–50
GST
24ADKPT5796M1ZK
IEC code
Not shared
Export markets
Global markets
GlobalLinker Member Since
Apr 2025
Turnover
Incorporation Type
On request
Product details

What are the specifications of this product?

Overview

Ceramic and Polymer electrical insulators preventing the flow of electric current. Used in HT/LT overhead lines

Product Description

Ceramic and Polymer electrical insulators preventing the flow of electric current. Used in HT/LT overhead lines

Description provided by make sure engineers.

Specifications

Voltage Rating Ranges from low tension (up to 1 kV) to high tension levels (up to 33 kV and beyond)
Creepage Distance Optimized based on voltage and environmental conditions
Operating Temperature Range -40°C to +120°C
Standards Compliance Conforms to IEC 61109, IS 3639, and IS 2071 for insulator quality
Dimensions Varies by model and design; available in disc, pin, and post configurations
Material Composition Ceramic (porcelain) or polymer housing with fiberglass core
Color Typically white or gray for ceramic; black for polymer
Mechanical Load Capacity Designed to handle mechanical loads due to conductor tension and wind

Use cases

Category Electrical Equipment > Transmission & Distribution Equipment > Insulators
Primary application Wholesale, distribution, and international sourcing
Brand Not specified
Product type Product

Logistics & handling

Lead time On request
Packaging As per buyer requirement
Storage condition As recommended by supplier
Origin India
Form As listed by supplier

Commercials (this seller)

Minimum order 1 unit
Lead time On request
Payment terms As per negotiated commercial agreement.
Checkout type enquiry
Buyer questions

Frequently asked by buyers

Common questions B2B buyers ask before sourcing Electrical insulators. Answers compiled from verified sellers' commercial terms and platform data.

Q: What are the major differences between ceramic and polymer electrical insulators for overhead lines?
A: Ceramic insulators offer high mechanical strength, excellent heat resistance, and longer proven service life; however, they are heavier and more brittle. Polymer insulators are lightweight, have superior resistance against vandalism, and perform better in polluted environments but may have shorter service life under extreme UV exposure.
Q: Can these insulators be used interchangeably for HT and LT lines?
A: The insulators are designed specifically for voltage ratings corresponding to HT or LT lines. Proper selection based on voltage level, mechanical load, and environmental conditions is critical to ensure safety and performance.
Q: What international and Indian standards do these electrical insulators comply with?
A: These insulators comply with IEC 61109 for composite insulators, IS 3639 for high voltage porcelain insulators, and IS 2071 for testing procedures, aligning with Indian regulatory requirements.
Q: What are the maintenance requirements for ceramic versus polymer insulators?
A: Ceramic insulators require regular inspection for cracks or chips but are generally low maintenance. Polymer insulators require monitoring for housing degradation, especially UV-induced aging, but are resistant to contamination and vandalism.
Q: Are these insulators suitable for extreme weather conditions such as heavy rain or pollution-prone areas?
A: Yes, both ceramic and polymer insulators are designed for outdoor use with resistant materials. Polymer insulators particularly perform well in polluted or coastal areas due to hydrophobic surfaces reducing contamination build-up.
Question not answered? Ask sellers directly — typical response within 4 hours.