1/2

Agni 16 Line Emergency Voice Communication FFT System - Digital EVCS Firefighter Telephone & Emergency Communication System

Agni Instruments Engineers India Pvt Ltd logo
Agni Instruments Engineers India Pvt Ltd
Manufacturer, Brand Owner — South Delhi, Delhi, India · Replies in ~24–48 hours
Export Ready
₹ 589.47 /PC In stock
Inclusive of all taxes
MOQ: 1 PC
Lead time: On request
GST invoice
Origin: India
Export ready
Buyer protection
Interested in this product?
Share your requirement and the seller will respond with a quote.
Comparing multiple suppliers?
Receive quotations from multiple verified suppliers and compare price & lead time.
Other buying options
Buyer-protected enquiry Seller responds in ~24–48 hours Freight & duties quoted separately
Export Snapshot
Minimum order
1 PC
HSN Code
15311020
Origin
India
Lead time
On request
Port of dispatch
On request
Packaging
Standard export packaging
Shelf life / storage
As per product specification
Export markets served
Global markets
Ability to customise
As per OEM brief
Values shown are for Agni Instruments Engineers India Pvt Ltd.
Company Agni Instruments Engineers India Pvt Ltd
Agni Instruments Engineers India Pvt Ltd logo
Agni Instruments Engineers India Pvt Ltd

Company registration intro only contact information or United Arab Emirates ,South Africa , Sri Lanka , Bangladesh, Bhutan, Nepal, Thailand, Vietnam, Istanbul , Morocco, Maldives ,India, The Middle East, And Southeast Asia. This Makes Agni Instruments Engineers India Private Limited. A Recognized Name In Fire Safety Worldwide. Agni Instruments Engineers India Private Limited Products Meet World-Class Standards And Ensure Safety And Reliability For Diverse Industrial And Commercial Applications.

Registered address: South Delhi, India. Industry: Tools, Machinery & Components › Instrumentation Equipment & Services.

View profile →
Established
1970
Employees
51–100
GST
07AABCA3553G1ZZ
IEC code
Not shared
Export markets
Global markets
Member since
Aug 2026
Turnover
$1 MM - $2 MM
Incorporation type
On request
Product details
The Agni 16 Line Emergency Voice Communication FFT System is an advanced Emergency Voice Communication System (EVCS) designed to provide organized monitoring and communication between emergency communication field points and the central control room.
The system features a large, high-resolution LCD display that provides clear, real-time information about system status, multiple call events, fault conditions, and operational menus. Its alphanumeric event display is designed to handle multiple simultaneous events in an organized, queue-based manner, allowing control room operators to quickly identify incoming calls and line faults.
The system supports multi-attempt event tracking, allowing operators to monitor several communication activities simultaneously without losing track of individual events. This is particularly useful in emergency situations where multiple field communication points may require attention at the same time.
For digital firefighter telephone systems and emergency communication field jack point risers exceeding 3,000 m using 1.5 mm² 2-core cable, a digital EVCS architecture is recommended. Since a 3 km riser exceeds the standard B-Class riser capacity of most conventional EVCS panels, the system should be planned using a networked or segmented architecture rather than relying on one continuous line.
The system can also support an advanced intelligent call priority and silent queue concept for busy emergency communication environments. When an incoming call is intentionally silenced or remains unanswered, the call can remain pending without continuous nuisance ringing. If another call subsequently arrives on a different line, the new call can reactivate an audible alert while the earlier silent call remains in the queue. This approach helps operators manage multiple emergency calls while ensuring new incoming calls regain their attention.
________________________________________
Key Features:
16-line Emergency Voice Communication System 
Large, high-resolution LCD display 
Real-time system status monitoring 
Multiple call event display 
Fault condition indication 
Alphanumeric event monitoring 
Organized event queuing for multiple simultaneous calls 
Multi-attempt event tracking 
Clear incoming call identification 
Line fault identification 
Designed for digital firefighter telephone and emergency communication systems 
Suitable for extended field communication risers 
Networked or segmented architecture suitable for long-distance applications 
Intelligent call priority and silent queue functionality concept 
Automatic re-alerting for new incoming calls while earlier calls remain pending 
________________________________________
System Specifications:
Product Name: Agni 16 Line Emergency Voice Communication FFT System 
System Type: Emergency Voice Communication System (EVCS) 
Communication Lines: 16 Lines 
Display: High-Resolution LCD 
Display Type: Alphanumeric 
Event Monitoring: Multiple Call Events 
Fault Monitoring: Line Fault Conditions 
Event Management: Queue-Based Monitoring 
Event Tracking: Multi-Attempt Event Tracking 
Extended Riser Application: Above 3,000 m 
Referenced Cable: 1.5 mm² 2-Core Cable 
Architecture for Extended Riser: Networked / Segmented 
Communication Application: Digital Firefighter Telephone / Emergency Communication 
________________________________________
Intelligent Call Priority & Silent Queue:
A key operational requirement for busy emergency communication systems is the ability to manage several incoming calls without overwhelming the control room operator.
The described system architecture supports a silent pending call and automatic re-ring on a new incoming line concept:
1. An incoming emergency call is received on Line A. 
2. The operator intentionally silences the call or leaves it unanswered. 
3. The original call remains pending in the queue. 
4. A new emergency call arrives on Line B. 
5. The system activates an audible ringing alert for the new incoming call. 
6. The earlier call remains preserved in the queue for subsequent attention. 
This approach helps prevent continuous ringing from causing operators to permanently mute emergency alerts while ensuring that new incoming emergency calls regain operator attention.
________________________________________
Long-Distance Digital EVCS Architecture:
For digital firefighter telephone systems where field jack point risers exceed 3,000 metres on 1.5 mm² 2-core cable, the supplied product information recommends using a networked or segmented digital EVCS architecture rather than treating the entire distance as one continuous conventional riser.
This configuration is particularly relevant for large facilities and distributed emergency communication installations where communication points may be located considerable distances from the central control room.
________________________________________
Applications:
Suitable for:
High-Rise Buildings 
Large Commercial Complexes 
Industrial Facilities 
Hospitals 
Shopping Malls 
Airports 
Large Institutional Buildings 
Fire Alarm Control Rooms 
Emergency Communication Networks 
Digital Firefighter Telephone Systems 
Emergency Voice Communication Systems 
Large Distributed Fire & Life Safety Installations 
________________________________________
Operational Benefits:
High-Resolution Event Monitoring:
The large LCD provides clear visibility of system status, incoming calls, faults, and operational menus.

Multiple Event Management:
The queue-style event display helps operators manage multiple simultaneous communication events in an organized manner.

Fast Fault Identification:
Line fault information is displayed to help operators identify communication issues quickly.

Multi-Event Tracking:
Multi-attempt event tracking allows several communication activities to be monitored without losing individual event information.


Description provided by Agni Instruments Engineers India Pvt Ltd.

Emergency Voice Communication System (EVCS)

16 Lines

Large High-Resolution LCD

Alphanumeric

Queue-Based Monitoring

Line Fault Conditions

Above 3,000 m

1.5 mm² 2-Core Cable

Networked / Segmented

1 PC

Specifications
Product Name
Agni 16 Line Emergency Voice Communication FFT System
System Type
Emergency Voice Communication System (EVCS)
Communication Lines
16 Lines
Display
High-Resolution LCD
Display Type
Alphanumeric
Event Monitoring
Multiple Call Events
Fault Monitoring
Line Fault Conditions
Event Management
Queue-Based Monitoring
Event Tracking
Multi-Attempt Event Tracking
Extended Riser Application
Above 3,000 m
Referenced Cable
1.5 mm² 2-Core Cable
Architecture for Extended Riser
Networked / Segmented
Communication Application
Digital Firefighter Telephone / Emergency Communication
MOQ
1 PC
Store Name
AGNI INSTRUMENTS ENGINEERS INDIA PVT LTD
Use cases
Category
Emergency Voice Communication Systems
Primary application
Brand
Not specified
Product type
Product
Logistics & handling
Lead time
On request
Packaging
As per buyer requirement
Storage condition
As recommended by supplier
Origin
India
Form
As listed by supplier
Commercials Agni Instruments Engineers India Pvt Ltd
Minimum order
1 PC
Lead time
On request
Payment terms
As per negotiated commercial agreement
Frequently asked by buyers
What is the line capacity of this EVCS panel?

This system is specified as a 16-line Emergency Voice Communication System, making it suitable for multi-point emergency communication and control-room monitoring.

Does the system support fault monitoring?

Yes. The display provides line fault condition indication so operators can quickly identify communication issues.

What type of display does it use?

It uses a large high-resolution LCD with an alphanumeric event display for real-time status, calls, faults, and menus.

Can it handle multiple emergency calls at the same time?

Yes. The system is designed for multiple call events, queue-based monitoring, and multi-attempt event tracking.

Is this suitable for long-distance riser applications?

Yes. For extended field communication risers above 3,000 m using 1.5 mm² 2-core cable, the product information recommends a networked or segmented architecture.

What is the recommended architecture for long risers?

A networked or segmented digital EVCS architecture is recommended instead of treating the full distance as one continuous conventional riser.

What is the MOQ for procurement?

The minimum order quantity is 1 PC.

Which facilities is this system suitable for?

It is suitable for high-rise buildings, large commercial complexes, industrial facilities, hospitals, shopping malls, airports, and large institutional buildings.

Question not answered? Sellers typically reply within 24–48 hours.

What similar products are available in this category?

Browse all →
water tank overflow alarm with malayalam voice message | loud sound GST VERIFIED
water tank overflow alarm with malayalam voice message | loud sound
Kjmindia
From $ 3.29
MOQ 1 Numbers
full and low tank alarm circuit board with a push switch to turn off the alarm GST VERIFIED
full and low tank alarm circuit board with a push switch to turn off the alarm
Kjmindia
From $ 3.29
MOQ 1 PC
sos alarm panic emergency switch button GST VERIFIED
sos alarm panic emergency switch button
Gray Logix
From $ 2.83
MOQ 1 Piece
honeywell fc-talarm01 alarm module GST VERIFIED
honeywell fc-talarm01 alarm module
Voltedge Trade
From $ 100.00
MOQ 1 UNT
notifier lem-320 loop expander module GST VERIFIED
notifier lem-320 loop expander module
Voltedge Trade
From $ 150.00
MOQ 1 UNT
notifier cps-24e intelligent power supply board GST VERIFIED
notifier cps-24e intelligent power supply board
Voltedge Trade
From $ 500.00
MOQ 1 UNT
notifier ncm-w network communications module GST VERIFIED
notifier ncm-w network communications module
Voltedge Trade
From $ 300.00
MOQ 1 UNT
4mdlg series deluge valve with alarm system
4mdlg series deluge valve with alarm system
Aira 4Matic Global Valve Automation Pvt. Ltd.
From $ 970.69
MOQ 1 Numbers

More from Agni Instruments Engineers India Pvt Ltd

View all →
1 to 4 loop addresable fire alarm control panel - mrico processor based intelligent
1 to 4 loop addresable fire alarm control panel - mrico processor based intelligent
$ 896.67
MOQ 1 Piece
agni veiga series intelligent addressable loop sounder / horn cum strobe – wall mounted
agni veiga series intelligent addressable loop sounder / horn cum strobe – wall mounted
$ 38.09
MOQ 1 PC
agni veiga addressable fire alarm repeater panel
agni veiga addressable fire alarm repeater panel
$ 579.26
MOQ 1 NOS
signature 2000 probe heat detector | fixed temperature fire sensor (ip42)
signature 2000 probe heat detector | fixed temperature fire sensor (ip42)
$ 34.01
MOQ 1 PC
agni equipment rack – 19” enclosed equipment rack series
agni equipment rack – 19” enclosed equipment rack series
$ 226.72
MOQ 1 PC
simplex slave talk back unit metal enclosure – agni 416
simplex slave talk back unit metal enclosure – agni 416
$ 7.94
MOQ 1 PC
firefighter stainless steel phone jack plate - agni ssj-ft-904-a - ssj-ft-905-b - firefighter telephone jack for evcs
firefighter stainless steel phone jack plate - agni ssj-ft-904-a - ssj-ft-905-b - firefighter telephone jack for evcs
$ 11.34
MOQ 1 PC
firefighter telephone handset enclosure - ffth-901-box - fire fighter telephone cabinet for ff901 handset
firefighter telephone handset enclosure - ffth-901-box - fire fighter telephone cabinet for ff901 handset
$ 17.00
MOQ 1 PC
Agni 16 Line Emergency Voice Communication FFT System -  Digital EVCS Firefighter Telephone & Emergency Communication System
Agni 16 Line Emergency Voice Communication FFT System - Digital EVCS Firefighter Telephone & Emergency Communication System
₹ 589.47 /PC