Blood Tubing Set (Pre-Pump, Post-Pump, Premium)
Membrane, Flux Class & Surface Area
Blood Tubing Set (Pre-Pump, Post-Pump, Premium) is a complete single-use bloodline assembly used to connect patient vascular access, pump, dialyzer, and return circuit during dialysis. The premium designation typically indicates enhanced tubing materials or integrated features to improve handling and reduce kinking. Clinical buyers evaluate tubing compatibility with their machines, pump heads, and dialyzer ports to ensure leak-free connections and consistent blood flow during treatment.
Compatibility & Consumable Dependency
These tubing sets are built to interface with standard dialysis machine connectors and dialyzer ports. They are part of the session consumable set including needles, dialyzers, and clamps. Procurement teams must verify pump head compatibility, connector type, and any integrated sensor or port features when placing orders to avoid mismatched assemblies.
High Flux Dialyzer
Membrane, Flux Class & Surface Area
High Flux Dialyzer is designed for hemodialysis treatments requiring increased convective clearance. High-flux membranes typically offer larger pore sizes and higher ultrafiltration coefficients to support enhanced middle-molecule removal. Procurement decisions focus on membrane material, surface area, and compatibility with existing machine transmembrane pressure ranges. Clinics select high-flux models to match prescribed treatment protocols and patient clearance targets.
Compatibility & Consumable Dependency
Dialyzers must be mechanically and hydraulically compatible with the clinic's dialysis machines and bloodline connectors. Selection includes checking priming volume, recommended blood flow ranges, and connector interface. Procurement should align dialyzer inventory with machine models and clinician preferences to avoid cross-compatibility issues.
Double Station Dialyzer Processor Machine
Membrane, Flux Class & Surface Area
Double Station Dialyzer Processor Machine supports parallel processing of two dialyzers for reprocessing, testing, or validation tasks in centralized clinical sterilization units. Machines of this class are configured to perform cleaning cycles, leak testing, and performance checks as part of a reprocessing workflow. Procurement should match processor throughput to clinic volume and ensure electrical and water supply compatibility at the installation site.
Compatibility & Consumable Dependency
Processor machines require compatible connectors, cleaning reagents, and drainage arrangements. They integrate with local utilities and may need consumable cartridges for filtration or reagent dosing. Buyers must plan space, utility connections, and staff training to operate and maintain equipment reliably.
Automatic Dialysis Chair
Membrane, Flux Class & Surface Area
The Automatic Dialysis Chair is an ergonomically designed patient chair intended to improve comfort and positioning for hemodialysis sessions. Features may include adjustable reclining, motorized positioning, and integrated accessory mounts for poles or tubing routing. Facility procurement teams consider chair durability, upholstery materials, and adjustability to meet patient throughput and cleaning protocols.
Compatibility & Consumable Dependency
Chairs must fit within station footprints and allow safe access for staff and equipment. They should permit secure routing of bloodlines and permit routine cleaning between patients. Consider integration with existing floor plans and transfer assist devices when planning replacements or new installations.
120 Litre Bicarbonate Mixture
Membrane, Flux Class & Surface Area
The 120 Litre Bicarbonate Mixture is a ready-format concentrate supplied to facilities that perform central mixing or require a large on-site buffer reserve. This large-volume format reduces changeover frequency for high-throughput dialysis centers. Clinical teams value the consistency of formulation and the reduction in manual handling compared with multiple small containers.
Compatibility & Consumable Dependency
Large-volume bicarbonate mixtures are suited to pump-fed mixing stations and require suitable storage and dispensing equipment. Facilities should ensure they have compatible fittings and handling equipment to decant product safely into dosing systems. Consider packaging access, weight handling, and spill containment in procurement planning.
SS RO Plant (100–3000 LPH)
Membrane, Flux Class & Surface Area
SS RO Plant (100–3000 LPH) is a stainless-steel-framed reverse osmosis water purification system sized for dialysis and medical water requirements. Capacity ranges from point-of-use small clinics up to large centers requiring higher throughput. Selection focuses on permeate flow, recovery rates, and membrane staging to meet required resistivity and contaminant removal targets for dialysate preparation.
Compatibility & Consumable Dependency
RO plants rely on pre-filtration cartridges, membrane elements, and periodic chemical cleaning consumables. Procurement planning should include spare part kits, membrane replacement schedules, and service agreements. Confirm source water characteristics to size pre-treatment appropriately.
FRP RO Plant (100–3000 LPH)
Membrane, Flux Class & Surface Area
FRP RO Plant (100–3000 LPH) offers a fiberglass-reinforced polymer skid option for RO water purification. FRP frames are corrosion-resistant and suitable where stainless steel is not required. Capacity selection is driven by clinic throughput needs and membrane staging to meet dialysis water quality specifications.
Compatibility & Consumable Dependency
FRP plants use the same pre-filters and reverse osmosis membranes as SS units but may differ in skid mounting and access panels. Procurement should determine spare parts planning and service access for routine membrane replacement and sanitization cycles.
Portable RO Plant (70 LPH)
Membrane, Flux Class & Surface Area
Portable RO Plant (70 LPH) is a compact reverse osmosis system sized for small clinics, mobile units, or as a backup water source. Its footprint and mobility make it suitable for point-of-use applications where permanent installations are impractical. Selection criteria include permeate quality, ease of transport, and quick commissioning.
Compatibility & Consumable Dependency
The portable plant uses standard pre-filters and RO membranes and typically includes quick-connect fittings for rapid setup. Consumable planning includes cartridge replacements and periodic sanitization supplies. Buyers should confirm inlet water characteristics to ensure stable operation.
Refurbished Dialysis Machine (Various Brands)
Membrane, Flux Class & Surface Area
Refurbished Dialysis Machine (Various Brands) offers a remanufactured option for clinics seeking cost-effective replacement equipment. Refurbishment typically includes mechanical overhaul, electrical testing, and functional validation to return the unit to operational condition. Buyers should specify accepted brand models and required reconditioning standards when requesting refurbished equipment.
Compatibility & Consumable Dependency
Refurbished machines must be checked for compatibility with existing disposables, bloodlines, and dialysis cartridges. Service history, parts replacement, and availability of spare parts are important procurement criteria to ensure long-term support for refurbished units.
Fresenius Refurbished 400085
Membrane, Flux Class & Surface Area
Fresenius Refurbished 400085 is a brand-specific reconditioned dialysis machine returned to operational readiness through mechanical and electrical servicing. Buyers selecting a refurbished Fresenius unit should request the refurbishment checklist, replaced components, and test outcomes to validate performance. This SKU is targeted at clinics that prefer brand consistency while managing capital costs.
Compatibility & Consumable Dependency
Verify that the refurbished Fresenius unit is compatible with your facility's consumables and dialyzers. Confirm spare-part availability and software versioning as part of procurement to ensure ongoing maintenance support.
Fresenius Refurbished 400085 NG
Membrane, Flux Class & Surface Area
The Refurbished 400085 NG is presented as a model-level dialysis system variant for institutional use. Refurbishment focuses on restoring core hemodialysis controls and compatibility interfaces. Refurbishment testing covers operational checks and consumable interface alignment to ensure the unit functions with standard bloodlines and dialyzers.
Compatibility & Consumable Dependency
This unit is sized to integrate with common dialyzer connectors and hospital bloodline sets. Procurement teams evaluate compatibility with local consumable inventories and replacement part availability. Refurbished units are best selected where maintenance support and spare-parts access are planned.
Solvent Tray
Containment Capacity & Material
Solvent Trays provide bench-level containment for reagent and solvent bottles to manage minor spills and prevent surface contamination. Typical materials include chemical-resistant plastics designed to withstand common laboratory solvents. Tray capacity and lip height determine containment volume, and buyers specify tray dimensions based on bench layout and bottle footprint. Procurement teams prioritize trays that match lab safety protocols and storage workflows.
Bench Integration & Safety Features
Design features include raised grids, non-slip surfaces, and compatibility with standard bottle sizes for secure placement. Trays aid in organizing reagent lines and enhancing spill response procedures. Institutional purchasers commonly order trays in bulk for standardization across workstations.
Solvent Bottles
Material & Chemical Compatibility
Solvent Bottles are laboratory-grade containers used for storage and handling of solvents and reagents. Common materials include amber glass for light-sensitive solvents and chemical-resistant plastics such as HDPE for aggressive solvents. Selection is driven by chemical compatibility, solvent volatility, and storage duration. Procurement teams choose bottle material and closure type based on the solvent class, safety requirements, and handling workflows in analytical or formulation labs.
Pack Sizes & Closure Types
Bottles are available in multiple pack sizes with screw caps, PTFE-lined seals, and dispensing closures. Buyers specify volumes and closure compatibility to ensure leak-free transport and safe dispensing routines. Institutional purchasers often order bulk packs to standardize reagent handling across laboratory suites.
Injector Valve Holder
Compatibility & Mounting Specifications
The Injector Valve Holder secures autosampler injector valves within HPLC systems and spare-part inventories. Buyers verify dimensional mounting interfaces and model compatibility to ensure proper fit. This component is relevant to maintenance teams, instrument service technicians, and procurement managers responsible for spare-part availability. Selecting the correct holder reduces instrument downtime during routine servicing.
Material & Durability Considerations
Common materials include stainless steel and coated alloys for corrosion resistance under solvent exposure. Durability and precision machining ensure repeatable valve alignment and leak-free operation. Procurement of spare parts is often planned around service cycles to maintain instrument uptime.
MS-800 Plus
Stirring Capacity & Motor Specifications
The MS-800 Plus Magnetic Stirrer is designed for routine laboratory mixing, supporting a range of stirring speeds and magnetic coupling strengths suited to small- to medium-volume vessels. It is selected by labs for reproducible agitation during sample prep, dissolution testing, and reagent mixing. Technical buyers evaluate torque performance, speed stability, and platform dimensions when standardizing stirrers across lab benches.
Temperature Control & Plate Construction
Models may include heated plates with uniform temperature distribution for controlled heating during mixing. Plate material and chemical resistance are important for durability in solvent-rich environments. Procurement decisions factor in electrical specifications and compatibility with local power systems.
20-ML Plus
Compact Performance & Speed Range
The 20-ML Plus Magnetic Stirrer is designed for small-volume mixing tasks and sample preparation in analytical and QC laboratories. Its compact platform supports microbeakers and small flasks, offering a precise speed range suited to gentle agitation or rapid mixing. Laboratory technicians value compact stirrers for benchtop workflows and repetitive sample processing tasks where space is limited.
Vessel Compatibility & Mounting
Compatibility with small vessels and reliable magnetic coupling are key selection points. The unit provides stable stirring for volumes around 20 ml, and buyers evaluate magnet strength and plate surface properties when standardizing small-volume mixing tools.
5-MLH Plus
Small-Volume Heating & Stirring
The 5-MLH Plus Heated Magnetic Stirrer is engineered for micro-volume mixing with controlled temperature for small-sample workflows. It suits laboratories handling micro-reactions and reagent conditioning where space and precision are priorities. Temperature stability and low-volume mixing performance are critical for reproducible results in analytical and R&D contexts.
Control Precision & Chemical Resistance
Precise temperature and speed controls minimize variation during small-scale processes. Plate materials are chosen for resistance to common lab solvents and for long-term durability under repeated heating cycles.
10-MLH Plus
Heated Plate & Temperature Stability
The 10-MLH Plus Heated Magnetic Stirrer combines compact stirring with controlled temperature capability for small-volume reactions and reagent preparation. It is suited to workflows requiring gentle heating and mixing for small sample volumes. Temperature uniformity and setpoint stability are primary selection factors when using heated stirrers for reproducible reactions and sample conditioning.
Speed Control & Small-Volume Performance
Precise speed control and stable magnetic coupling enable consistent mixing across small vessels. Buyers selecting heated variants evaluate thermal ramp behavior and plate corrosion resistance for long-term reliability.
5-ML Plus
Compact Stirring & Magnetic Coupling
The 5-ML Plus Magnetic Stirrer provides compact, reliable stirring for small-volume laboratory tasks. It is suitable for benchtop mixing, sample preparation, and small-batch reagent handling. Selection criteria include magnet strength, control precision, and footprint compatibility with existing laboratory benches. Procurement teams choose compact stirrers to standardize small-volume workflows across multiple benches.
Footprint & Power Requirements
Consideration of voltage and footprint ensures compatibility with local power systems and bench layouts. Buyers should confirm power specifications and required quantity when requesting procurement quotations.
3-RML
Mixing Capability & Speed Range
The 3-RML Laboratory Mixer provides reliable benchtop mixing for routine sample processing and reagent blending. It is sized for small to medium sample volumes and offers variable speed control for gentle to vigorous mixing profiles. Selection focuses on torque performance and speed stability for consistent sample outcomes.
Vessel Compatibility & Controls
Compatibility with a range of vessel sizes and robust control interfaces simplify integration into lab workflows. Procurement groups specify vessel types and expected usage patterns when ordering to ensure the mixer meets operational needs.
2-RML
Operational Speed & Torque
The 2-RML Laboratory Mixer offers reliable small-bench mixing with adjustable speeds and sufficient torque for common laboratory tasks. It is designed for sample preparation, reagent blending, and other routine mixing operations. Buyers focus on consistent speed control and fixture compatibility for varied vessel types.
Fixture Compatibility & Footprint
Compact footprint and adaptable fixtures allow compatibility with multiple vessel formats. Procurement teams order mixers to standardize bench equipment and minimize bench-space conflicts across laboratory suites.
1-RML
Design & Mixing Performance
The 1-RML Laboratory Mixer is a compact benchtop unit designed for routine mixing and sample preparation tasks. It offers stable speed control and reliable operation for small laboratory workflows. Selection focuses on control simplicity, footprint, and fixture compatibility for common vessel sizes used in QC and R&D.
Controls & Installation Requirements
Simple control interfaces and standard electrical requirements make the unit easy to integrate into laboratory benches. Procurement teams can standardize the mixer across multiple stations for consistent sample processing routines.
Heparin Sodium Injection — 25000 IU
Strength, Dosage Form & Pack Configuration
Heparin Sodium Injection 25,000 IU is a high-strength anticoagulant formulation used in clinical settings, including dialysis and surgical procedures where institutional anticoagulation protocols require concentrated vials. Procurement teams typically request the exact vial size and presentation when sourcing to ensure compatibility with infusion and dosing workflows. Confirm the licensed commercial presentation when submitting an RFQ.
Dosage-Form-Specific Handling & Administration Context
As a parenteral anticoagulant, handling follows institutional clinical and pharmacy procedures. Procurement and clinical teams coordinate on storage, administration, and documentation aligned with local protocols.
On and Off Kit
Membrane, Flux Class & Surface Area
The On and Off Kit is a consumable accessory kit designed to support dialysis session setup and disconnection workflows. It typically contains connection fittings and single-use components to enable safe and efficient patient circuit management. Dialysis centres procure these kits to standardize session setup and minimize connection errors during routine hemodialysis operations.
Compatibility & Consumable Dependency
The kit is selected for compatibility with specific dialysis machine connectors and bloodlines. Procurement should confirm connector types and required component specifications when ordering.