1/1

Fresenius Dialysis Machine 4008 S The next generation

Shakti Power Solutions Pvt Limited logo
Shakti Power Solutions Pvt Limited
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler — Amritsar, Punjab, India · Replies in ~24–48 hours
FIEO Registered Export Ready
Price on request In stock
MOQ: 1 unit
Lead time: On request
GST invoice
Origin: India
Export ready
Buyer protection
Interested in this product?
Share your requirement and the seller will respond with a quote.
Comparing multiple suppliers?
Receive quotations from multiple verified suppliers and compare price & lead time.
Other buying options
Buyer-protected enquiry Seller responds in ~24–48 hours Freight & duties quoted separately
Export Snapshot
Minimum order
1 unit
HSN Code
On request
Origin
India
Lead time
On request
Port of dispatch
On request
Packaging
Standard export packaging
Shelf life / storage
As per product specification
Export markets served
Global markets
Ability to customise
As per OEM brief
Values shown are for Shakti Power Solutions Pvt Limited.
Company Shakti Power Solutions Pvt Limited
Shakti Power Solutions Pvt Limited logo
Shakti Power Solutions Pvt Limited

Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals › Diagnostic Centres & Laboratories.

FIEO Registered
View profile →
Established
Not shared
Employees
–
GST
03ABGCS0227D1ZZ
IEC code
Not shared
Export markets
Global markets
Member since
Dec 2018
Turnover
$2 MM - $5 MM
Incorporation type
On request
Product details

Clinical Hemodialysis Architecture and Fluid-Handling Logic of the 4008 S

The technical framework of the Fresenius Dialysis Machine 4008 S utilize a complex network of dosing pumps, heater modules, and volumetric scales governed by a redundant microprocessor system. The structural reasoning for this architecture is to provide "closed-loop control" of the dialysate preparation; the machine automatically mixes ultrapure water with concentrate at precise ratios. A failure in the proportioning logic—due to sensor drift or pump fatigue—results in "electrolyte imbalance," which manifests as erratic conductivity and can trigger catastrophic patient reactions. measurement physics rely on redundant conductivity and temperature sensors to validate the dialysate before it enters the dialyzer. If any parameter deviates from the setpoint, the safety bypass valve executes an immediate diversion of the fluid to drain, preventing the patient from exposure to incorrect concentrations. The chassis is constructed with a patient-side isolation barrier to minimize microbial contamination. Quality consistency is managed through serialized calibration records that document the accuracy of the blood pump and ultrafiltration (UF) regulation, ensuring the unit meets the technical specifications of institutional healthcare providers.

Functional Performance and Operational Stability in High-Throughput Wards

Operational efficiency is achieved through the unit’s automated self-test sequences and calibration prompts, which reduce the manual setup time for nursing staff. functional performance centers on the unit’s ability to maintain stable UF rates across 4-6 hour treatments; failure to manage fluid removal precisely results in "hemodynamic instability," leading to patient discomfort or dangerous hypotension events. The 4008 S utilize modular pump and sensor assemblies that facilitate in-situ servicing; if a pump fails during a shift, the modular strategy allow for rapid replacement without full system removal, effectively lowering the MTTR. In real operational scenarios, a failure in the disinfection cycle—due to poor heater performance or sensor error—leads to "bacterial seeding" in the fluid manifold, decommissioning the machine for intensive chemical cleaning. The system include telemetry outputs for treatment logging, providing the B2B facility manager with the audit trails required for clinical compliance. thermal management is critical for the heater block; internal temperature sensors execute a hard shutdown if the dialysate exceeds 40°C, protecting the blood circuit from hemolysis.

Institutional Deployment and Logistical Readiness for medical Equipment

Designed for hospitals and centrally managed dialysis centers, the 4008 S is configured for the logistical requirements of multimodal procurement. Units ship in protective crates with internal timber bracing and moisture-barrier covers to protect the sensitive fluid modules and electronics from shock and humidity during sea freight. Failure to implement shock-rated packaging results in "chassis racking," which manifests as microscopic leaks in the fluid manifolds upon site startup. For international procurement, supply-readiness is supported through component-level traceability and factory functional test reports provided with each unit (ISO 13485). Export-ready documentation include unit-level calibration logs and technical dossiers provided to satisfy regulatory checks and customs review. Packaging utilize anti-vibration inserts to prevent component misalignment during transport. OEM/private label options permit integration of facility-specific user interfaces and branded chassis elements. This high-authority approach ensure the procurement team receives verified, site-ready medical assets that meet the safety and performance standards of global healthcare markets, providing the transparency required for institutional asset registration and maintenance planning.

Frequently Asked Questions

  • What quality checks are performed before dispatch? Every unit undergoes 100% functional verification, fluid-path integrity testing, and full calibration.
  • How is integration with hospital IT systems managed? Standard digital and analog I/O are provided; integration pinouts and protocols are supplied in the technical dossier.
  • What is the expected service interval? Service intervals are load-dependent; recommended inspections for pumps and seals are defined in the maintenance schedule.
  • What packaging standard is used for transport? Protective crating with internal bracing and moisture-resistant covers protect against shock and corrosion.
  • Which documents support customs clearance? Shipments include test certificates, calibration logs, and an institutional technical dossier.
Description provided by Shakti Power Solutions Pvt Limited.

Fresenius Dialysis Machine 4008 S - The Next Generation

250 Liters Per Hour (LPH)

Stainless Steel

Manual

2

Water Purification, Ultra Filtration Plant, Dialysis Water Treatment

Electric

1 Year

Made in India

Pan India

In Stock

1 Unit

Specifications
Reverse Osmosis Capacity
250 LPH
Construction Material
Stainless Steel
Automation Type
Manual Control
Number of Membranes in RO System
2
Primary Application
Dialysis Water Treatment / Water Purification Plant
Power Requirements
Electric Power Source
Warranty Period
1 Year
Country of Manufacture
India
Minimum Order Quantity
1 Unit
Delivery Availability
Pan India
Use cases
Category
Medical Equipment > Dialysis Equipment > Dialysis Machines
Primary application
Product type
Product
Logistics & handling
Lead time
On request
Packaging
As per buyer requirement
Storage condition
As recommended by supplier
Origin
India
Form
As listed by supplier
Commercials Shakti Power Solutions Pvt Limited
Minimum order
1 unit
Lead time
On request
Payment terms
As per negotiated commercial agreement
Frequently asked by buyers
What is the reverse osmosis capacity of the Fresenius Dialysis Machine 4008 S?

The Fresenius Dialysis Machine 4008 S has a reverse osmosis capacity of 250 liters per hour, ensuring efficient water purification for dialysis.

How many RO membranes are integrated into the Fresenius 4008 S dialysis machine?

This model includes 2 RO membranes to provide enhanced filtration and purification performance.

Is the Fresenius Dialysis Machine 4008 S automated or manual?

The machine features manual automation control, allowing healthcare professionals to customize dialysis parameters.

What material is the Fresenius Dialysis Machine 4008 S made from?

The machine is constructed from high-grade stainless steel to ensure durability and hygiene compliance.

What is the warranty period provided for the Fresenius Dialysis Machine 4008 S?

The product comes with a one-year warranty covering manufacturing defects and performance issues.

Question not answered? Sellers typically reply within 24–48 hours.

What similar products are available in this category?

Browse all →
willmar schwabe alpha ts (tension and stress) (30ml) GST VERIFIED
willmar schwabe alpha ts (tension and stress) (30ml)
Ayurbella
From $ 11.99
MOQ 1 Numbers
bilirubin meter GST VERIFIED
bilirubin meter
Anantya Bionics
Price on request
MOQ 1 unit
ecg machine GST VERIFIED
ecg machine
Anantya Bionics
Price on request
MOQ 1 unit
ot table GST VERIFIED
ot table
Anantya Bionics
Price on request
MOQ 1 unit
cautery machine GST VERIFIED
cautery machine
Anantya Bionics
Price on request
MOQ 1 unit
c arm surgery machine GST VERIFIED
c arm surgery machine
Anantya Bionics
Price on request
MOQ 1 unit
arm sling pouch GST VERIFIED
arm sling pouch
Marvel Medi Revolutions
From $ 5.10
MOQ 300 NOS
posture correction belt - long GST VERIFIED
posture correction belt - long
Marvel Medi Revolutions
From $ 11.34
MOQ 1 Unit

More from Shakti Power Solutions Pvt Limited

View all →
shakti power solutions optiflux 6300 - electromagnetic flowmeter
shakti power solutions optiflux 6300 - electromagnetic flowmeter
Price on request
MOQ 1 unit
shakti power solutions powerflux 5030 - electromagnetic flowmeter, water
shakti power solutions powerflux 5030 - electromagnetic flowmeter, water
Price on request
MOQ 1 unit
shakti power solutions 1-3 kva eaton 9e external battery model
shakti power solutions 1-3 kva eaton 9e external battery model
Price on request
MOQ 1 unit
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
shakti power solutions optitemp tca-p20 thermocouple (tc) temperature assembly for standard applications
Price on request
MOQ 1 unit
shakti power solutions eaton 9e - 1 kva online ups without batteries, 100vac-300vac
shakti power solutions eaton 9e - 1 kva online ups without batteries, 100vac-300vac
Price on request
MOQ 1 unit
shakti power solutions waterflux 3100 - electromagnetic flowmeter
shakti power solutions waterflux 3100 - electromagnetic flowmeter
Price on request
MOQ 1 unit
shakti power solutions optiflux 6050 - electromagnetic flowmeter, water
shakti power solutions optiflux 6050 - electromagnetic flowmeter, water
Price on request
MOQ 1 unit
shakti power solutions optiflux 1050 - electromagnetic flowmeter
shakti power solutions optiflux 1050 - electromagnetic flowmeter
Price on request
MOQ 1 unit
Fresenius Dialysis Machine 4008 S The next generation
Fresenius Dialysis Machine 4008 S The next generation
Price on request