Delta UPS EH Series - 10/15/20 kVA
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Sold by shakti power solutions pvt limited · Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Importers · Distributors · Wholesalers
shakti power solutions pvt limited is a Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler based in Amritsar Punjab India.
Service Provider , Manufacturer, Professional Services, Retailer, Distributor, Exporter, Importer, Wholesaler · Amritsar, Punjab, India
Registered address: Amritsar, India. Industry: Healthcare, Medical Supplies & Pharmaceuticals > Diagnostic Centres & Laboratories.
Delta UPS EH Series – 10/15/20 kVA Modular UPS SystemDelta UPS EH Series is a three-phase power protection platform offering modular power electronics and redundant control pathways for commercial and industrial conditioning. Utilizing a convertible rack/tower chassis, the system delivers conditioned output in 10 kVA, 15 kVA, or 20 kVA configurations, supporting high availability for data centers and process control rooms. The unit architecture includes configurable bypass logic and hot-swappable power modules to minimize mean time to repair (MTTR) without interrupting critical loads. Units are produced with manufacturing capacity to support large-order procurement, featuring palletized crates with vibration protection and lot traceability. Supply-readiness is managed through per-unit functional tests and burn-in logs, addressing the requirements of facility managers requiring right-sized, scalable power protection with documented performance baselines for site acceptance and integration into industrial energy management protocols.Key FeaturesModular kVA scaling (10/15/20) → provides selection flexibility to match facility power demand growth and right-size for initial load profiles.Redundant control architecture → utilizes dual processors to eliminate single-point failures and ensure continuous system oversight during maintenance.Hot-swappable module design → enables on-line servicing and power module replacement without requiring facility-wide power shutdowns.Technical AttributesPower Configurations: 10/15/20 kVA → selection parameter defining redundancy and runtime autonomy targets.Thermal Management: Forced-air with monitored intake → maintains stable operating temperatures for semiconductors and capacitors.Control Interfaces: SNMP/Modbus/Relay → selection for direct integration with building management and DCIM systems.Supply Readiness: Serialized functional test reports → provided per unit to validate site commissioning standards.
The technical framework of the Delta UPS EH Series utilize a modular inverter-rectifier architecture where the power conversion stages are decoupled by a common DC bus. The structural reasoning for this modularity is to provide "fault isolation"—a failure in one power module—due to capacitor breakdown or IGBT failure—can be isolated immediately, allowing the redundant module or static bypass to maintain the output sine wave. Without this specific architecture, a localized component failure would decommission the entire three-phase system, leading to catastrophic downtime for connected IT or medical equipment. The mechanical layout segregates the power electronics from the sensitive control circuitry, reducing electromagnetic interference (EMI) and localized heat coupling. Power stage PCBs are conformal-coated to resist moisture-induced tracking, a critical standard for units deployed in unconditioned industrial plant rooms. Quality consistency is managed through serialized test reports that record the unit's THDv (Voltage Total Harmonic Distortion) and regulation accuracy under 100% load step changes. Failure to maintain these tolerances leads to "load hunting" and increased thermal stress on the downstream server power supplies.
Operational efficiency is achieved through the system’s high-efficiency double-conversion mode, which provides continuous isolation from grid disturbances while maintaining low operating costs. The EH Series utilize variable-speed fans that modulate based on real-time load and temperature data; a failure in the fan speed control results in excessive acoustic noise or localized overheating of the DC-link capacitors. Functional performance centers on the unit’s ability to handle high crest-factor loads typical of industrial control centers. The integrated charger management system execute temperature-compensated charging for internal or external VRLA banks. Failure to compensate for temperature—especially in warm data rooms—leads to "thermal runaway" and battery swelling, effectively reducing the energy storage capacity by 50%. If the system detects a catastrophic bus fault, the configurable bypass logic executes a zero-break transfer to mains, provided the sources are synchronized. Integrated telemetry provides real-time state-of-health (SoH) metrics and event logs via Modbus, allowing B2B facility managers to implement predictive maintenance and accurately account for the energy throughput of the critical power system.
Appropriate for commercial complexes, small-to-medium data centers, and industrial process rooms, the Delta EH Series is configured for the logistical requirements of large-order procurement. Units ship in palletized crates with anti-vibration fixtures and humidity-control liners to protect the delicate inverter electronics during multimodal transit. Failure to implement shock-mitigating packaging can lead to "latent defects" in the transformer mounts, resulting in high-impedance joints and localized hotspots upon site commissioning. For international projects, supply-readiness is supported through serialized functional verification reports and compliance declarations (CE/IEC). Export-ready documentation include configuration images, firmware versioning cards, and electrical safety certificates provided with each lot. Packaging utilize moisture-barrier wrapping and desiccant to prevent corrosion of the high-current connectors during maritime freight. OEM branding and private-label configuration options are available for system integrators requiring branded power protection suites. This systematic approach ensure procurement teams receive verified, site-ready hardware that meet the rigorous technical and safety performance standards required for international infrastructure deployments.
Description provided by shakti power solutions pvt limited.
| Capacity Options | 10 kVA, 15 kVA, 20 kVA |
|---|---|
| Input Voltage | 175~280 VAC |
| Output Voltage | 230 VAC |
| Form Factor | 2U Rack Mounted |
| Output Power Factor | Unity |
| Efficiency (AC-AC) | Up to 96.5% |
| Efficiency (ECO Mode) | 99% |
| Battery Type | Li-ion External Battery Cabinets |
| Parallel Operations | Supports up to 4 Units in Parallel |
| Typical Applications | Servers, Data Centers, Telecom, Manufacturing |
| MOQ | 1 Unit |
| Category | Electricals > Power Backup & UPS Systems > UPS Systems > Rack Mounted UPS |
|---|---|
| Primary application | Wholesale, distribution, and international sourcing |
| Brand | shakti power solutions |
| Product type | Product |
| Lead time | On request |
|---|---|
| Packaging | As per buyer requirement |
| Storage condition | As recommended by supplier |
| Origin | India |
| Form | As listed by supplier |
| Minimum order | 1 unit |
|---|---|
| Lead time | On request |
| Payment terms | As per negotiated commercial agreement. |
| Checkout type | enquiry |